91J Quartermaster and Chemical Equipment Repairer flashcards and quiz
Drill 87 91J flashcards on one page. They are grouped into 3 decks, starting with “Deep Dive 3: Duties, Water/Heater/BDAR Tasks, LADS and CBL Laundry….” Read a question, say your answer, then check it.
- 87 cards
- 3 decks
- Quiz mode
How to drill 91J
- Pick one deck below and cover the answers with your hand or a sheet of paper.
- Maintenance decks have many parts and troubleshooting steps. Drill one system at a time.
- When a deck feels easy, open 91J in the app and choose Practice test. It asks multiple-choice questions built from these same cards.
With 87 cards, try about 4 short rounds of 25 cards instead of one long session. One or two rounds a day keeps it fresh.
91J decks on this page
- 91J – Deep Dive 3: Duties, Water/Heater/BDAR Tasks, LADS and CBL Laundry Systems50 cards
- 91J – Quartermaster and Chemical Equipment Repairer15 cards
- CMF 91/94 – Army Maintenance Common Knowledge22 cards
91J – Deep Dive 3: Duties, Water/Heater/BDAR Tasks, LADS and CBL Laundry Systems
Source: DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91J; STP 9-91J12-SM-TG Quartermaster and Chemical Equipment Repairer (19 Sep 2019); ATP 4-33 Maintenance Operations (9 Jan 2024), appendix A desert heat/sand paras (not used in other CMF 91 files). Supplementary study aid – verify against current editions on armypubs.army.mil.
- 91J: How is the CBL water treatment system first filled?
- Run Cycle 01, INITIAL FILL, on one washer only; it takes about 15 minutes.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 7a
- 91J: How does the CBL Automatic Soap Dispenser show a chemical is depleted?
- An alarm sounds and a signal light on a control module shows which chemical to replenish.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 5a
- 91J: Which engine systems does a skill level 1 91J maintain?
- Internal combustion engine ignition, fuel, cooling and electrical systems.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Ja(1)
- 91J: What is the highest skill level for 91J in the 2026 DA Pam?
- Skill level 2 (91J2O).
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Ja(1)-(2)
- 91J: What ASVAB scores qualify for 91J?
- MM 87, or a combination of MM 82 and GT 85.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Jb(6)(a)
- 91J: What physical requirements apply to 91J?
- Profile 222222, normal color vision, finger dexterity in both hands, and no petroleum allergy.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Jb(2) to b(5)
- 91J: Where does DA Pam 611-21 point for 91J ACASP criteria?
- Table 9-1, the list of MOSs approved for ACASP.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Jb(6)
- 91J: What must happen before dispensing water from purification equipment?
- Have the water tested by medical personnel.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1018 (WARNING)
- 91J: What lubricant must never be used in the water system?
- Petroleum-based lubricants.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1018 (WARNING)
- 91J: Up to what temperature does the 91J PMCS task cover extreme-heat operation?
- Up to 125°F.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1018, step 3
- 91J: Where should coolant be kept in extreme heat?
- About two inches below the radiator overflow pipe, if so equipped.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1018, step 3b
- 91J: Which form is completed after PMCS on QM and chemical equipment?
- DA Form 5988-E.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1018, step 7
- 91J: What must the hoist used to lift water tanks from water tank chests be rated for?
- At least 750 pounds.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1006 (DANGER)
- 91J: When performing BDAR on QM equipment, what do you check for on arrival?
- NBC contamination and booby traps, then locate the damage.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1019, step 4
- 91J: What MOPP decision is made before deploying to a BDAR site?
- Don the MOPP level based on the NBC reports.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1019, step 3a
- 91J: Where does BDAR-repaired QM equipment go afterward?
- To the maintenance collection point, with the inspection worksheet forwarded to the shop supervisor or foreman.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1019, step 9
- 91J: How far from the shelter should a personnel heater be placed?
- About 7 ft (2,134 mm), with the duct openings facing the shelter connections.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1017 (CAUTION)
- 91J: How unlevel is too unlevel for a personnel heater?
- More than 8½ degrees from horizontal.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1017 (CAUTION)
- 91J: What fire extinguisher should be on standby where a personnel heater runs?
- A 50-lb carbon dioxide extinguisher.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1017 (WARNING)
- 91J: What heater-mode limit applies above +70°F?
- Don't run the heater in heating mode longer than 10 minutes.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1017 (WARNING)
- 91J: How do you prevent a static spark when fueling a personnel heater?
- Keep metal-to-metal contact between the fuel container and the fuel tank.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1017 (DANGER)
- 91J: What must be run before removing power from the LADS?
- A cool-down cycle, because thermal fluid can reach about 400°F.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024 (WARNING)
- 91J: What load limits apply to each LADS drum?
- No more than 200 lb and no less than 50 lb of laundry.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024 (CAUTION)
- 91J: Why is chlorine bleach never used in the LADS?
- It makes hydrochloric acid in the still, which rapidly deteriorates the still, condenser and plumbing.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024 (CAUTION)
- 91J: What generator setting powers the LADS from an MEP-805A?
- 210 VAC, 60 Hz.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024, steps 1-2
- 91J: Why might the LADS CONTROL POWER lamp stay off?
- A monitor found incorrect electrical phasing with the external power source.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024, step 30 note
- 91J: What air pressure must the LADS reach before utility operations are fully selectable?
- 80 psi.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024, step 33 note
- 91J: What is the allowable LADS rinse-water heating range?
- 70 to 160 degrees. Out-of-range settings return to the 150-degree default.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024, step 40 note
- 91J: How long does a typical LADS laundry cycle last?
- 65 to 75 minutes.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024, step 53 note
- 91J: How long does a normal LADS cool-down last?
- About 30 minutes.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1024, step 55 note
- 91J: Which TM governs CBL operation?
- TM 10-3510-226-10. CBL maintenance tasks use TM 10-3510-226-23.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027 and -1028
- 91J: What must be connected before CBL start-up?
- Power, a source water fabric bag and a graywater fabric bag.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 2b
- 91J: What pressures do you watch while priming the CBL P-1 pump?
- Bleed air at about 25 psi and wait for about 60 psi.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 4f
- 91J: What if the CBL P-1 pump won't prime after a second attempt?
- Notify unit maintenance.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 4g
- 91J: What should you do if the CBL boiler shuts down a second time?
- Shut it off at the PLC and notify unit maintenance. Don't attempt a second restart.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 6d
- 91J: What happens if the CBL boiler runs out of fuel?
- Unit maintenance must bleed air from the boiler fuel system.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 6e
- 91J: What is the minimum CBL reuse tank temperature after the initial fill?
- 110°F.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 7o
- 91J: What reuse water temperature should the CBL hold, and what is the max?
- About 120°F, never above 125°F.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 8c
- 91J: How long should you wait after a CBL mixing valve adjustment?
- At least 45 minutes, adjusting one increment at a time.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 8d
- 91J: Which CBL cycle purges the nanofilters daily?
- Cycle 31, NANO FILTER FLUSH/CLEAN.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 10d
- 91J: Which CBL cycle neutralizes chlorine in the nanofilters?
- Cycle 32, NANO FILTER STORAGE (sodium bisulphite).
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 10d
- 91J: How often may CBL Cycle 30 (reuse tank top-off) be run?
- No more than once every four hours, and only when no water shows in the sight glass.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 10f
- 91J: Which CBL cycles skip water reuse if the reuse system fails?
- Cycles 08, 09 and 10.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1027, step 10c
- 91J: Which desert parts does ATP 4-33 call high-consumption?
- Filter elements, tires, water pumps, gaskets, fan belts, coolant hoses, clamps, sprocket nuts, seals and wedge bolts.
- ATP 4-33 (9 Jan 2024), para A-3
- 91J: Why are cooling and lubrication systems watched together in heat?
- They are interdependent: a fault in one quickly strains the other.
- ATP 4-33 (9 Jan 2024), para A-7
- 91J: How much coolant does one drip per second waste in 24 hours?
- About seven gallons.
- ATP 4-33 (9 Jan 2024), para A-8
- 91J: Why not remove engine hood side panels while running?
- It causes turbulence and leads to ineffective cooling.
- ATP 4-33 (9 Jan 2024), para A-8
- 91J: What does sand mixed with oil form?
- An abrasive paste, so check lube fittings often.
- ATP 4-33 (9 Jan 2024), para A-13
- 91J: How should sandy electrical connectors be handled?
- Brush them out, for example with an old toothbrush, before joining.
- ATP 4-33 (9 Jan 2024), para A-15
- 91J: Where does overnight desert condensation collect?
- On surfaces cooler than the air, such as optics and air tanks.
- ATP 4-33 (9 Jan 2024), para A-20
91J – Quartermaster and Chemical Equipment Repairer
Source: DA Pam 611-21 (Smartbook, Nov 2025), ch. 10C (10-91J), table 10-1; AR 750-1 (29 Apr 2026); DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026) (DA Pam 750-8 inactive on APD; see DA Pam 750-1 (29 Apr 2026)); ATP 4-33 (9 Jan 2024); goordnance.army.mil (Ordnance School training locations); STP 9-91J12-SM-TG (19 Sep 2019). Equipment TMs are mostly distribution-restricted – verify in the current TM.
- 91J: What is the primary role of the 91J?
- Status: current MOS (DA Pam 611-21 ch. 10C). Supervises or performs field-level maintenance on chemical equipment, quartermaster machinery, forced-air heaters and special purpose equipment – heaters, liquid pumps and pumping systems, tactical and lightweight reverse osmosis water purification systems, decontamination systems, protective filter systems, smoke generators and laundry systems, plus their engines; performs BDAR.
- DA Pam 611-21 (Smartbook, Nov 2025), ch. 10C (10-91J, para a(1))
- 91J: What equipment examples do 91Js repair?
- Tactical/lightweight water purification systems, laundry systems (e.g., LADS, containerized batch laundry), decontaminating apparatus, liquid pumps, personnel heaters, protective filter systems and smoke generators.
- DA Pam 611-21 (Smartbook, Nov 2025), ch. 10C (10-91J para a(1)); STP 9-91J12-SM-TG (19 Sep 2019), tasks 091-91J-1001 to -1031
- 91J: What hazard is common to this work?
- Exposure to fuels, chemicals, and pressurized systems – use PPE and follow SDS guidance.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1001 WARNING (dangerous chemicals, gasoline, high voltage); 29 CFR 1910.1200(g) (SDS)
- 91J: Where is 91J AIT?
- 91J training is conducted under the auspices of the U.S. Army Ordnance School; the Ordnance School lists 91J training at Fort Lee, VA (formerly Fort Gregg-Adams) – verify current course length with your recruiter/ATRRS.
- DA Pam 611-21 (Smartbook, Nov 2025), ch. 10C (10-91J, para b, formal training); goordnance.army.mil/schools/VA_lee.html (Ordnance training location – Fort Lee, VA; retrieved 22 Nov 2026); HQDA GO 2025-16 (Fort Gregg-Adams redesignated Fort Lee, 11 Jun 2025)
- 91J: Where do 91Js work?
- Maintenance and quartermaster support units that operate water, fuel, laundry, and decon equipment.
- ATP 4-33 (9 Jan 2024), paras 2-41 (support maintenance company), 2-67 (field maintenance company), 2-73 (FSC)
- 91J: What water equipment do 91Js maintain?
- Water purification units, pumps, storage and distribution equipment.
- STP 9-91J12-SM-TG (19 Sep 2019), tasks 091-91J-1006 to -1014 (water purification equipment); DA Pam 611-21 (Smartbook, Nov 2025), ch. 10C (10-91J para a(1))
- 91J: What fuel equipment do 91Js maintain?
- Fuel pumps, filter/separators, and dispensing equipment.
- DA Pam 611-21 (Smartbook, Nov 2025), ch. 10C (10-91J para a(1): liquid pumps and pumping systems); filter/separator and dispensing examples: Unofficial – common unit practice/SOP; not found in official doctrine
- 91J: What is a filter/separator?
- A unit that removes particulate and water from fuel.
- Unofficial – common unit practice/SOP; not found in official doctrine
- 91J: What decontamination equipment might 91Js repair?
- Power-driven decontamination apparatus and related pumps/heaters – verify fielded systems.
- STP 9-91J12-SM-TG (19 Sep 2019), tasks 091-91J-1001 to -1004 (decontaminating apparatus fuel, water, heating and electrical systems)
- 91J: What is a common engine type on QM equipment?
- Small diesel engines driving pumps and generators.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1016 (diesel engine assembly); DA Pam 611-21 (Smartbook, Nov 2025), ch. 10C (10-91J para a(1): internal combustion engines)
- 91J: What safety concern applies to fuel equipment repair?
- Fire and vapors – ground equipment, eliminate ignition sources, and contain spills.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1017 WARNING (do not operate in fuel vapor areas; static spark from fuel flow)
- 91J: What is PMCS's role for QM equipment?
- Operators find faults early; 91Js correct faults beyond operator level.
- AR 750-1 (29 Apr 2026), para 3-9a-b; ATP 4-33 (9 Jan 2024), para 1-25
- 91J: What is the skill progression for 91J?
- SL1 repairer (E-3/E-4); SL2 team leader (SGT) – 91J is graded only E-3 to E-5. 10C lists 91J duties only at SL1-2; at SL3, MOS 91C (Utilities Equipment Repairer) performs 91J duties. 91J is not among the courses listed for 91X.
- DA Pam 611-21 (Smartbook, Nov 2025), Fig 10-1, table 10-1; ch. 10C (10-91J para a(1)-(2); 10-91C para a(3); 10-91X para b(6))
- 91J: What field feeding equipment might 91Js repair?
- Burners, refrigeration, and mechanical components of field kitchens.
- Not independently verified – DA Pam 611-21 (Smartbook, Nov 2025), ch. 10C (10-91J para a) lists "quartermaster machinery, forced air-heaters" but not field kitchens by name; likely in the restricted 91J STP/equipment TMs (CAC)
- 91J: What hazard exists with pressurized water systems?
- Pressure release and hose whip; depressurize before disconnecting.
- STP 9-91J12-SM-TG (19 Sep 2019), task 091-91J-1018 WARNING (do not open hose couplings under pressure; hose whip)
CMF 91/94 – Army Maintenance Common Knowledge
Source: AR 750-1 (29 Apr 2026), Army Materiel Maintenance Policy; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), Army Materiel Maintenance Procedures (replaces DA Pam 750-8, inactive on APD TAMMS forms/procedures); ATP 4-33 (9 Jan 2024), Maintenance Operations; DA Pam 25-40 (1 Feb 2024) (TM numbering); AR 700-139 (30 Apr 2025); AR 11-42 (4 May 2026); DA Pam 611-21 (Smartbook, Nov 2025), ch. 10 (CMF 91/94); 29 CFR 1910 (OSHA). Applies to 91- and 94-series maintainers.
- CMF 91: What are the TM "dash numbers" and what do they mean?
- Level-of-maintenance numbers: -10 operator/crew; -12 operator through maintainer; -20 maintainer (field) maintenance. Suffix "P" = a separately published repair parts and special tools list (RPSTL), e.g., -20P; "&P" = RPSTL included in the same TM (e.g., -20&P). Older multi-level numbers such as -23/-24 still appear on legacy TMs.
- DA Pam 25-40 (1 Feb 2024), para 8-26d and f, table 8-5; ATP 4-33 (9 Jan 2024), app C, para C-2 (legacy TMs not yet converted to two-level)
- CMF 91: What is the Maintenance Allocation Chart (MAC)?
- The TM section that designates authority and responsibility for performing maintenance functions on an item. Field maintenance may perform tasks coded C, O and F; sustainment adds H, and depot/AMC-designated activities L and D, when skilled maintainers, tools and TMDE are available.
- ATP 4-33 (9 Jan 2024), app C, paras C-1, C-3, C-4; AR 750-1 (29 Apr 2026), para 3-8b
- CMF 91: What is the Army maintenance standard (TM 10/20 standard)?
- One mandatory standard, defined by the TM-10 and TM-20 series. Equipment meets it when all nine conditions exist: (1) it is FMC; (2) all faults are identified at the prescribed intervals using the PMCS "items to be checked" column; (3) all field-level repairs and services for which parts are available are done; (4) parts not on hand are requisitioned per AR 710-2; (5) work the MAC does not authorize at field level goes to sustainment with turn-in documentation; (6) scheduled services are done at the TM/MAM interval (10% variance allowed; past it the item is NMC); (7) MWOs, safety-of-use and other maintenance messages are applied and recorded in the MMIS; (8) all authorized BII and COEI are present and serviceable or on valid requisition; (9) maintenance advisory/information messages directing software updates are applied and reported in the MMIS.
- AR 750-1 (29 Apr 2026), para 3-2a and b(1)-(9)
- CMF 91: What does FMC, PMC, and NMC mean?
- Fully Mission Capable (safe, all mission-essential subsystems operating; no "not FMC ready if" faults); Partially Mission Capable (can perform at least one but not all missions – AR 750-1 defines PMC for aircraft and training devices); Not Mission Capable (cannot perform any one of its combat missions; split into NMC-maintenance and NMC-supply).
- AR 750-1 (29 Apr 2026), glossary (FMC, NMC, NMC-M, NMC-S, PMC); ATP 4-33 (9 Jan 2024), paras 4-37, 4-38
- CMF 91: What is a QDR?
- Product Quality Deficiency Report (PQDR) – reports deficient (e.g., defective new) parts or materiel. PQDRs and EIRs are submitted through the Product Data Reporting and Evaluation Program (PDREP) or on SF 368; instructions are in DA Pam 738-751.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-7a; AR 750-1 (29 Apr 2026), para 2-12n
- CMF 91: What is an EIR?
- Equipment Improvement Recommendation – reports a design, operation or maintenance-instruction shortcoming so it can be evaluated for changes. Filed with PQDRs through PDREP or on SF 368 (DA Pam 738-751).
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-7a
- CMF 91: What is "cannibalization," and is it allowed?
- Cannibalization is removing serviceable parts from unserviceable, generally uneconomically repairable, items; it is permitted only where authorized (e.g., authorized cannibalization points under AR 710-2/DA Pam 710-2-2, or limited cases before turn-in to DLA Disposition Services). Controlled exchange is different: removing serviceable parts from unserviceable but economically repairable end items for immediate reuse, allowed only under AR 750-1 para 4-11 conditions (part not available within the IPD, valid requisition submitted, donor NMC-S, removal recorded on the 5990-E/5988-E).
- AR 750-1 (29 Apr 2026), paras 4-11, 8-10a, 9-2b; glossary (Cannibalization – see DoDI 4151.18); DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 5-1 (operation of cannibalization points when authorized)
- CMF 91: What is a maintenance meeting?
- A recurring command meeting reviewing equipment status, parts on order, services due, and maintenance priorities.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-26d (MCO reviews and communicates maintenance status through maintenance meetings)
- CMF 91: What is the 91X MOS?
- Maintenance Supervisor (SFC, MOSC 91X4O). Soldiers come from the 91B, 91C, 91D, 91E, 91F, 91H and 91L courses. 91A, 91M, 91P and 91S have their own SL4 and, with 91X, feed 91Z (MSG/SGM; titled Mechanical Maintenance Supervisor in table 10-1, Senior Maintenance Supervisor in 10C).
- DA Pam 611-21 (Smartbook, Nov 2025), table 10-1; ch. 10C (10-91X, para b(6); 10-91Z, para b(3))
- CMF 91: What is the 94W MOS?
- Electronic Maintenance Supervisor (SFC); 94Z Senior Electronic Maintenance Supervisor at MSG/SGM.
- DA Pam 611-21 (Smartbook, Nov 2025), table 10-1 (94W4 E7; 94Z5/94Z6 E8-E9)
- CMF 91: What is lockout/tagout?
- Isolating energy sources (electrical, hydraulic, pneumatic) and tagging them so equipment cannot be energized during maintenance.
- 29 CFR 1910.147 (Control of hazardous energy), para (a)(1)(i)
- CMF 91: What is an SDS?
- Safety Data Sheet – hazards, handling, PPE, and first aid for a hazardous material.
- 29 CFR 1910.1200 (Hazard Communication), para (g)
- CMF 91: What is a DA Form 5988-E (or the current equivalent equipment fault form)?
- DA Form 5988-E, Equipment Maintenance and Inspection Worksheet (EGA), produced from GCSS-Army: operators record PMCS faults and corrosion on it, and maintainers use it to document and correct them. Equipment with uncorrected NMC or safety-directive faults found in before-operations PMCS must not be dispatched until fixed. DA Pam 750-8 is inactive on APD; the form is now prescribed in DA Pam 750-1.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-1b(3)(c) and app A; AR 750-1 (29 Apr 2026), para 3-9b(1)
- CMF 91: What is dispatch, in maintenance terms?
- The controlled release of equipment for use: the commander designates a school-trained ERPS clerk to manage dispatch, which confirms the operator is qualified and PMCS is done to the maintenance standard, and records use on DA Form 5987-E (or 5987-1-E/DD 1970; DA Form 2401 only when automated dispatch is not possible). A normal dispatch is signed by the company commander or designated representative for up to 7 days.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-5e and f(1)
- CMF 91: What is AOAP?
- The Army Oil Analysis Program – lab analysis of component lubricants to support data-driven maintenance. Under AR 750-1 (2026) routine AOAP sampling applies only to Aviation Ground Support Equipment (hydraulic samples every 30 days); special samples may be sent from any weapon system when maintainers suspect contamination or impending engine, transmission or hydraulic failure.
- AR 750-1 (29 Apr 2026), para 12-2; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-2
- CMF 91: What is the difference between a scheduled service and unscheduled maintenance?
- A scheduled service (maintenance plan) is the TM- or MAM-required set of checks, adjustments and lubrication at a usage- or time-based interval (10% variance allowed). Unscheduled maintenance (fault repair) restores equipment to FMC after faults are found by PMCS, operation or breakdown. Both are recorded in GCSS-Army.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), paras 2-1a(2)-(3), 4-1c(1); AR 750-1 (29 Apr 2026), para 3-2b(6)
- CMF 91: What is a slave start, and what is the main safety concern?
- Using a NATO slave cable or approved method to start a vehicle from another vehicle's electrical system. Use the approved cable and procedures; incorrect hookup can damage electronics or cause injury. Follow the platform TM — not a civilian jumper-cable habit.
- Not independently verified – likely in restricted vehicle -10 operator TM (slave-start procedure) (CAC); check the current TM
- CMF 91: Why must you use jack stands or the TM-specified supports, not only a jack, when working under a vehicle?
- A jack is a lifting device, not a reliable support. Vehicles can slip or the jack can fail. The TM specifies approved support points and devices.
- 29 CFR 1926.600(a)(3)(i) (OSHA: equipment held aloft by jacks must be blocked or cribbed before anyone works under it); support points per the vehicle TM
- CMF 91: What is corrosion prevention and control (CPC) in Army maintenance?
- The Army CPC Program: cleaning, treating, painting and preserving equipment (operators annotate corrosion on the 5988-E and do corrective actions within their capability; unit corrosion monitors and CPC surveys support it), so corrosion does not cause faults or NMC conditions. Policy is in AR 11-42; maintenance aspects in AR 750-1 and DA Pam 750-1.
- AR 11-42 (4 May 2026); AR 750-1 (29 Apr 2026), para 12-16; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-1b(3)(b)-(c)
- CMF 91: What should a maintainer do with a fault that is not listed as NMC but is a safety problem?
- Record it, notify the supervisor, and do not ignore it. Deficiencies that render equipment NMC per the TM or violate a safety directive must be corrected before the mission; FMC equipment must also meet AR 385-10 and AR 700-138 provisions and be operable without endangering the crew.
- AR 750-1 (29 Apr 2026), para 3-9b(1); ATP 4-33 (9 Jan 2024), para 4-37
- CMF 91: What is a warranty claim on Army equipment, in brief?
- A warranty claim gets a warranted item repaired or replaced by the manufacturer/dealer or materiel developer when it fails during the warranty, instead of using unit resources. Units execute warranties per the MATDEV procedures in the warranty technical bulletin and local written instructions, coordinated through the warranty control office/coordinator.
- AR 700-139 (30 Apr 2025), paras 1-9a, 1-11; AR 750-1 (29 Apr 2026), para 2-10t
- CMF 91: How does CMF 91 relate to CMF 94 in a typical brigade?
- 91-series mechanics maintain automotive, armament, and similar mechanical systems; 94-series repairers maintain electronic, missile, radar, and other electronic systems. Both use the same maintenance levels, MAC, and GCSS-Army discipline, and both support the same combat formation.
- ATP 4-33 (9 Jan 2024), para 1-20 (two-level maintenance alignment); DA Pam 611-21 (Smartbook, Nov 2025), ch. 10 (CMF 91 and CMF 94 sections)
Keep going: more Mechanical Maintenance decks
- 91BWheeled Vehicle Mechanic222 cards
- 91DPower-Generation Equipment Repairer87 cards
- 91HTrack Vehicle Repairer87 cards
- 91LConstruction Equipment Repairer87 cards
- 91CUtilities Equipment Repairer85 cards
- 91EAllied Trades Specialist85 cards
Not your job? Use the MOS deck finder or see every MOS deck by career field.