Drill 91D: Power-Generation Equipment Repairer flashcards
This page puts every 91D card in one place: 87 questions and answers for the Power-Generation Equipment Repairer job, spread across 3 decks.
- 87 cards
- 3 decks
- Quiz mode
How to drill 91D
- Maintenance decks have many parts and troubleshooting steps. Drill one system at a time.
- Pick one deck below and cover the answers with your hand or a sheet of paper.
- When a deck feels easy, open 91D in the app and choose Practice test. It asks multiple-choice questions built from these same cards.
With 87 cards, try about 4 short rounds of 25 cards instead of one long session. One or two rounds a day keeps it fresh.
91D decks on this page
- 91D – Deep Dive 3: Duties, Command Post Power, Safety, and Hot/Cold Weather Maintenance50 cards
- 91D – Tactical Power Generation Specialist15 cards
- CMF 91/94 – Army Maintenance Common Knowledge22 cards
91D – Deep Dive 3: Duties, Command Post Power, Safety, and Hot/Cold Weather Maintenance
Source: DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91D; STP 9-91D13-SM-TG Tactical Power Generation Specialist (12 Oct 2018), tasks not used in other 91D files; ATP 4-33 Maintenance Operations (9 Jan 2024), appendix A desert and cold weather paras (not used in other CMF 91 files). Supplementary study aid – verify against current editions on armypubs.army.mil.
- 91D: What generator size range does 91D maintain?
- Power generation equipment from 0.5 kW to 500 kW, except turbine-engine-driven generators.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Da
- 91D: Does a 91D rebuild generators?
- No. 91Ds perform field maintenance, including overhaul, but not rebuild.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Da
- 91D: How does a skill level 1 91D support generator operators?
- By assisting operators in the proper employment of tactical power generation equipment.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Da(1)
- 91D: Name components a skill level 2 91D repairs or overhauls.
- Starters, alternators, generators, fuel injectors, voltage regulators, switches and control circuits.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Da(2)
- 91D: What planning duty does a skill level 2 91D perform?
- Serves as unit power planner and picks the right generator to meet power demands efficiently.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Da(2)
- 91D: What does a skill level 3 91D do as tactical power planner?
- Completes power assessments and tactical power grid designs, and advises staff on employing power equipment.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Da(3)
- 91D: What ASVAB scores qualify for 91D?
- GM 93, or a combination of GM 88 and GT 85.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Db(6)(a)
- 91D: What physical profile does 91D require?
- 222222, with normal color vision and finger dexterity in both hands.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Db(2) to b(4)
- 91D: What civilian jobs meet 91D ACASP criteria?
- 2 years as a powerhouse mechanic, power plant mechanic or gas-turbine power plant mechanic.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Db(6) (ACASP criteria)
- 91D: What is ASI C9 for 91D?
- MAST and Electric Power Plant Maintenance, for skill levels 1 and 2 only.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Dc(1)
- 91D: What generator range did the 2018 STP list for 91D, compared with the 2026 DA Pam?
- The 2018 STP said up through 200 kW. The Oct 2026 DA Pam says 0.5 to 500 kW.
- STP 9-91D13-SM-TG (12 Oct 2018), ch. 4 duty position; DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Da
- 91D: What safety precaution applies to all 91D STP tasks before work starts?
- Remove all rings, watches and jewelry, and don't run generators in an enclosed area without adequate ventilation.
- STP 9-91D13-SM-TG (12 Oct 2018), general WARNING repeated across tasks
- 91D: What must you never do while a generator is running?
- Connect or disconnect generator cables, or attempt repairs. High voltage is present.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-2001 and -2002 (DANGER)
- 91D: What PPE rule applies to the cooling fan?
- Wear gloves; the fan has sharp blades.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-1191 (WARNING)
- 91D: What hazard does hot coolant pose during cooling system work?
- Keep it off skin, face, eyes and hands, and wear protective gear at all times.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-1191 (DANGER)
- 91D: What PMCS intervals are in the 91D tactical power system PMCS task?
- Before, during and after operation, with all deficiencies recorded on the proper forms.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-1111
- 91D: What power plant supports a brigade main command post?
- The AN/MJQ-41 60 kW TQG power plant: two trailer-mounted 60 kW generators.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-2002, step 2a
- 91D: In the AN/MJQ-41, which generator is the A set?
- The one with the transfer box mounted on the tongue end of the trailer.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-2002, step 2a(1)
- 91D: What service does the brigade main CP power plant equal?
- A 200-amp commercial three-phase service at 120/208 VAC, 60 Hz.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-2002, step 2a(1)
- 91D: What breakers does an M100 PDISE have?
- One 100-amp, two 60-amp, two 40-amp and two 20-amp breakers.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-2002, step 2a(6)
- 91D: What household panel is the M100 compared to, and the M40?
- The M100 is like a main panel; the M40 is like a sub-panel or branch circuit panel.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-2002, step 2a(6)-(7)
- 91D: What does the M46 Electrical Utility Assembly provide?
- Cables, outlets and lights for the inside of the CP, connected to 20-amp connectors on the M100 or M40.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-2002, step 2a(8)
- 91D: What do 100-amp 50-ft service feeder cables connect?
- A 100-amp pigtail to the M100 PDISE, or a pigtail to another 100-amp feeder cable.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-2002, step 2a(10)
- 91D: What condition do you use to calculate power requirements in a power assessment?
- The worst-case condition.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-3131, step 2b
- 91D: What does the central power grid concentrate on in a TOC design?
- Mission load only. A secondary grid is added for ECU loads.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-3131, step 4d-4e
- 91D: What must a 91D power assessment report contain?
- Maximum measured loads, demand factors, recommended generation source and PDISE setup.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-3131 (standards)
- 91D: What does a Central Power Solution aim to do with generator counts?
- Replace many small 3 to 10 kW sets so units use fewer individual generators without hurting the mission.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-3131 (special condition and standards)
- 91D: Which forms are completed after a welding machine classification inspection?
- DA Form 5988-E and/or DA Form 5990-E.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-3124, step 8
- 91D: Which TM governs 91D load bank diagnostics?
- TM 9-6115-641-10.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-3126
- 91D: Which TM governs the C9 hydraulic-pneumatic mast and Electrical Power Plant III tasks?
- TM 11-5985-368-34.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-ASIC9-1002 to -1005
- 91D: Why keep power generation equipment from overheating in the desert?
- Excessive heat can cause system failure.
- ATP 4-33 (9 Jan 2024), para A-11
- 91D: What desert battery precautions does ATP 4-33 give?
- Keep vents clean so vapors don't build up and explode, set voltage regulators low, and stock more batteries.
- ATP 4-33 (9 Jan 2024), para A-9
- 91D: How often should air cleaners be checked in the desert?
- At least daily.
- ATP 4-33 (9 Jan 2024), para A-14
- 91D: How does heat affect closed systems?
- Pressure rises and liquids expand, so use caution removing filler caps.
- ATP 4-33 (9 Jan 2024), para A-10
- 91D: Why must generators be bonded and grounded in the desert?
- Dry terrain prevents static from grounding out, and a spark can ignite flammable gases.
- ATP 4-33 (9 Jan 2024), para A-25
- 91D: What happens to fuel tanks filled to the brim at night in the desert?
- They overflow as the day warms. Fill to TM capacity.
- ATP 4-33 (9 Jan 2024), para A-21
- 91D: At what temperature do cold weather operations start getting more difficult?
- Below -10°F. Below -40°F they become increasingly difficult.
- ATP 4-33 (9 Jan 2024), para A-30 and A-31
- 91D: Below -20°F, how much longer can maintenance take?
- Up to five times the normal time.
- ATP 4-33 (9 Jan 2024), para A-36
- 91D: How much do maintenance man-hours rise without heated shelters in cold weather?
- From 25 to 500 percent above normal.
- ATP 4-33 (9 Jan 2024), para A-38
- 91D: Why must power generation equipment be grounded in the arctic?
- To avoid system failure.
- ATP 4-33 (9 Jan 2024), para A-34
- 91D: What extra battery equipment is needed in subzero conditions?
- More battery chargers, plus hydrometers and testers to check state of charge.
- ATP 4-33 (9 Jan 2024), para A-42
- 91D: Why carry extra gloves during cold weather fuel and cooling system work?
- Fluids soak gloves, lose insulation and can cause cold injuries.
- ATP 4-33 (9 Jan 2024), para A-43
- 91D: How do you protect yourself from cold-soaked equipment?
- Avoid leaning on it or lying on the ground; put cardboard, rags or tarps between you and it.
- ATP 4-33 (9 Jan 2024), para A-44
- 91D: What happens to rubber and neoprene cable jackets in extreme cold?
- They harden and become brittle, so protect cables from shock and bending.
- ATP 4-33 (9 Jan 2024), para A-33
- 91D: How much can desert temperatures swing from day to night?
- In some deserts, more than 70°F.
- ATP 4-33 (9 Jan 2024), para A-1
- 91D: How do you reduce desert wind damage to tents and antennas?
- Use terrain protection and picket items firmly to the ground.
- ATP 4-33 (9 Jan 2024), para A-26
- 91D: Why does cold weather maintenance take longer?
- Equipment must be warmed up before repairs, and bulky clothing cuts efficiency.
- ATP 4-33 (9 Jan 2024), para A-35
- 91D: Name things that should be in place before a cold weather operation.
- Maintenance shelter, proper clothing and tools, ground cover, portable heaters, fluid storage, lighting, repair parts and snow removal gear.
- ATP 4-33 (9 Jan 2024), para A-37
- 91D: How can maintenance tents be improved in the cold?
- Lay wooden flooring and heat them with portable duct heaters or tent stoves.
- ATP 4-33 (9 Jan 2024), para A-38
- 91D: What lighting items are essential for maintenance operations?
- Lights with ample cable extensions, attachment plugs, connectors and spare bulbs.
- ATP 4-33 (9 Jan 2024), para A-40
91D – Tactical Power Generation Specialist
Source: DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91D), table 10-1; AR 750-1 (29 Apr 2026); DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026) (DA Pam 750-8 inactive on APD; see DA Pam 750-1 (29 Apr 2026)); ATP 4-33 (9 Jan 2024); goordnance.army.mil (Ordnance School training locations); STP 9-91D13-SM-TG (12 Oct 2018); ASA(ALT) Weapon Systems Handbook 2020-2021 (Tactical Electric Power). Equipment TMs are mostly distribution-restricted – verify in the current TM.
- 91D: What is the primary role of the 91D?
- Status: current MOS (DA Pam 611-21 ch. 10C). To maintain and repair tactical generators and power distribution equipment.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91D, para a)
- 91D: What generator family is common in the Army?
- The Advanced Medium Mobile Power Sources (AMMPS) generators (5–60 kW), replacing older Tactical Quiet Generators.
- ASA(ALT) Weapon Systems Handbook 2020-2021, Tactical Electric Power (TQGs and AMMPS, 5-60 kW medium generators); STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-1191 (AMMPS TMs)
- 91D: Why must generators be grounded?
- To protect personnel from electrical shock and equipment from faults.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-MCST-1000, step 3 (ground power plants: ground rod at least 8 ft deep, #6 AWG ground cable bonded to chassis)
- 91D: What is load balancing?
- Distributing electrical loads evenly across phases to prevent overload and improve efficiency.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-MCST-1000, step 8 (balance the load)
- 91D: What safety rules apply to generator refueling?
- Shut down and allow cooling when required, ground/bond, no smoking, and have a fire extinguisher present.
- Not independently verified – likely in restricted generator set operator TM (refueling warnings) (CAC); check the current TM
- 91D: Where is 91D AIT?
- 91D training is conducted under the auspices of the U.S. Army Ordnance School; the Ordnance School lists 91D training at Fort Lee, VA (formerly Fort Gregg-Adams) (reserve-component 91D courses are also taught at the RTS-Maintenance, Fort Leonard Wood, MO) – verify current course length with your recruiter/ATRRS.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91D, para b, formal training); goordnance.army.mil/schools/VA_lee.html (Ordnance training location – Fort Lee, VA; retrieved 22 Nov 2026); HQDA GO 2025-16 (Fort Gregg-Adams redesignated Fort Lee, 11 Jun 2025); goordnance.army.mil/schools/MO_wood.html (Ordnance training location – Fort Leonard Wood, MO; 91D 10/30 reserve-component courses at RTS-M; retrieved 22 Nov 2026)
- 91D: Where do 91Ds work?
- In units across the Army that rely on tactical generators, and in maintenance companies.
- ATP 4-33 (9 Jan 2024), paras 2-41 (support maintenance company), 2-67 (field maintenance company), 2-73 (FSC); DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91D para a(1)-(3): assists operators; unit power planner)
- 91D: What does kW rating mean for a generator?
- The real power output the generator can supply.
- Unofficial – common unit practice/SOP; not found in official doctrine
- 91D: What is the difference between single-phase and three-phase power?
- Single-phase uses one alternating voltage; three-phase uses three, offset in time, supporting larger loads more efficiently.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-1188 (single- and three-phase systems in power determination)
- 91D: What is a power distribution box?
- Equipment that distributes generator power safely to multiple loads with circuit protection.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-MCST-1000, step 5 (emplace PDISE M100/M40 feeder and distribution boxes)
- 91D: What is "wet stacking"?
- Unburned fuel buildup in diesel exhaust when generators run lightly loaded for long periods.
- Unofficial – common unit practice/SOP; not found in official doctrine
- 91D: What are common generator faults?
- Fuel problems, battery/starting failures, governor/voltage regulation issues, and overheating.
- STP 9-91D13-SM-TG (12 Oct 2018), tasks 091-91D-1101, -1181 to -1186, -1191 (control panel, main generator, governor, battery charging, lubrication, fuel, starting and cooling system malfunctions)
- 91D: What is generator paralleling?
- Connecting generators to share a load, requiring synchronization.
- STP 9-91D13-SM-TG (12 Oct 2018), task 091-91D-1189 (paralleling procedures; synchronizing lamps)
- 91D: What hazards exist with generator exhaust?
- Carbon monoxide – never run generators in enclosed spaces.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3004 WARNING (carbon monoxide in exhaust of internal combustion engines)
- 91D: What is the skill progression for 91D?
- SL1 specialist (E-3/E-4); SL2 team leader/supervisor (SGT); SL3 section/shop sergeant (SSG) – 91D is graded E-3 to E-6. At SFC, 91D Soldiers move to 91X Maintenance Supervisor, then 91Z (MSG/SGM). SL2/SL3s serve as unit/tactical power planners.
- DA Pam 611-21 (Oct 2026 copy), Fig 10-1, table 10-1; ch. 10C (10-91D para a(1)-(3); 10-91X para b(6); 10-91Z para b(3))
CMF 91/94 – Army Maintenance Common Knowledge
Source: AR 750-1 (29 Apr 2026), Army Materiel Maintenance Policy; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), Army Materiel Maintenance Procedures (replaces DA Pam 750-8, inactive on APD TAMMS forms/procedures); ATP 4-33 (9 Jan 2024), Maintenance Operations; DA Pam 25-40 (1 Feb 2024) (TM numbering); AR 700-139 (30 Apr 2025); AR 11-42 (4 May 2026); DA Pam 611-21 (Smartbook, Nov 2025), ch. 10 (CMF 91/94); 29 CFR 1910 (OSHA). Applies to 91- and 94-series maintainers.
- CMF 91: What are the TM "dash numbers" and what do they mean?
- Level-of-maintenance numbers: -10 operator/crew; -12 operator through maintainer; -20 maintainer (field) maintenance. Suffix "P" = a separately published repair parts and special tools list (RPSTL), e.g., -20P; "&P" = RPSTL included in the same TM (e.g., -20&P). Older multi-level numbers such as -23/-24 still appear on legacy TMs.
- DA Pam 25-40 (1 Feb 2024), para 8-26d and f, table 8-5; ATP 4-33 (9 Jan 2024), app C, para C-2 (legacy TMs not yet converted to two-level)
- CMF 91: What is the Maintenance Allocation Chart (MAC)?
- The TM section that designates authority and responsibility for performing maintenance functions on an item. Field maintenance may perform tasks coded C, O and F; sustainment adds H, and depot/AMC-designated activities L and D, when skilled maintainers, tools and TMDE are available.
- ATP 4-33 (9 Jan 2024), app C, paras C-1, C-3, C-4; AR 750-1 (29 Apr 2026), para 3-8b
- CMF 91: What is the Army maintenance standard (TM 10/20 standard)?
- One mandatory standard, defined by the TM-10 and TM-20 series. Equipment meets it when all nine conditions exist: (1) it is FMC; (2) all faults are identified at the prescribed intervals using the PMCS "items to be checked" column; (3) all field-level repairs and services for which parts are available are done; (4) parts not on hand are requisitioned per AR 710-2; (5) work the MAC does not authorize at field level goes to sustainment with turn-in documentation; (6) scheduled services are done at the TM/MAM interval (10% variance allowed; past it the item is NMC); (7) MWOs, safety-of-use and other maintenance messages are applied and recorded in the MMIS; (8) all authorized BII and COEI are present and serviceable or on valid requisition; (9) maintenance advisory/information messages directing software updates are applied and reported in the MMIS.
- AR 750-1 (29 Apr 2026), para 3-2a and b(1)-(9)
- CMF 91: What does FMC, PMC, and NMC mean?
- Fully Mission Capable (safe, all mission-essential subsystems operating; no "not FMC ready if" faults); Partially Mission Capable (can perform at least one but not all missions – AR 750-1 defines PMC for aircraft and training devices); Not Mission Capable (cannot perform any one of its combat missions; split into NMC-maintenance and NMC-supply).
- AR 750-1 (29 Apr 2026), glossary (FMC, NMC, NMC-M, NMC-S, PMC); ATP 4-33 (9 Jan 2024), paras 4-37, 4-38
- CMF 91: What is a QDR?
- Product Quality Deficiency Report (PQDR) – reports deficient (e.g., defective new) parts or materiel. PQDRs and EIRs are submitted through the Product Data Reporting and Evaluation Program (PDREP) or on SF 368; instructions are in DA Pam 738-751.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-7a; AR 750-1 (29 Apr 2026), para 2-12n
- CMF 91: What is an EIR?
- Equipment Improvement Recommendation – reports a design, operation or maintenance-instruction shortcoming so it can be evaluated for changes. Filed with PQDRs through PDREP or on SF 368 (DA Pam 738-751).
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-7a
- CMF 91: What is "cannibalization," and is it allowed?
- Cannibalization is removing serviceable parts from unserviceable, generally uneconomically repairable, items; it is permitted only where authorized (e.g., authorized cannibalization points under AR 710-2/DA Pam 710-2-2, or limited cases before turn-in to DLA Disposition Services). Controlled exchange is different: removing serviceable parts from unserviceable but economically repairable end items for immediate reuse, allowed only under AR 750-1 para 4-11 conditions (part not available within the IPD, valid requisition submitted, donor NMC-S, removal recorded on the 5990-E/5988-E).
- AR 750-1 (29 Apr 2026), paras 4-11, 8-10a, 9-2b; glossary (Cannibalization – see DoDI 4151.18); DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 5-1 (operation of cannibalization points when authorized)
- CMF 91: What is a maintenance meeting?
- A recurring command meeting reviewing equipment status, parts on order, services due, and maintenance priorities.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-26d (MCO reviews and communicates maintenance status through maintenance meetings)
- CMF 91: What is the 91X MOS?
- Maintenance Supervisor (SFC, MOSC 91X4O). Soldiers come from the 91B, 91C, 91D, 91E, 91F, 91H and 91L courses. 91A, 91M, 91P and 91S have their own SL4 and, with 91X, feed 91Z (MSG/SGM; titled Mechanical Maintenance Supervisor in table 10-1, Senior Maintenance Supervisor in 10C).
- DA Pam 611-21 (Smartbook, Nov 2025), table 10-1; ch. 10C (10-91X, para b(6); 10-91Z, para b(3))
- CMF 91: What is the 94W MOS?
- Electronic Maintenance Supervisor (SFC); 94Z Senior Electronic Maintenance Supervisor at MSG/SGM.
- DA Pam 611-21 (Smartbook, Nov 2025), table 10-1 (94W4 E7; 94Z5/94Z6 E8-E9)
- CMF 91: What is lockout/tagout?
- Isolating energy sources (electrical, hydraulic, pneumatic) and tagging them so equipment cannot be energized during maintenance.
- 29 CFR 1910.147 (Control of hazardous energy), para (a)(1)(i)
- CMF 91: What is an SDS?
- Safety Data Sheet – hazards, handling, PPE, and first aid for a hazardous material.
- 29 CFR 1910.1200 (Hazard Communication), para (g)
- CMF 91: What is a DA Form 5988-E (or the current equivalent equipment fault form)?
- DA Form 5988-E, Equipment Maintenance and Inspection Worksheet (EGA), produced from GCSS-Army: operators record PMCS faults and corrosion on it, and maintainers use it to document and correct them. Equipment with uncorrected NMC or safety-directive faults found in before-operations PMCS must not be dispatched until fixed. DA Pam 750-8 is inactive on APD; the form is now prescribed in DA Pam 750-1.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-1b(3)(c) and app A; AR 750-1 (29 Apr 2026), para 3-9b(1)
- CMF 91: What is dispatch, in maintenance terms?
- The controlled release of equipment for use: the commander designates a school-trained ERPS clerk to manage dispatch, which confirms the operator is qualified and PMCS is done to the maintenance standard, and records use on DA Form 5987-E (or 5987-1-E/DD 1970; DA Form 2401 only when automated dispatch is not possible). A normal dispatch is signed by the company commander or designated representative for up to 7 days.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-5e and f(1)
- CMF 91: What is AOAP?
- The Army Oil Analysis Program – lab analysis of component lubricants to support data-driven maintenance. Under AR 750-1 (2026) routine AOAP sampling applies only to Aviation Ground Support Equipment (hydraulic samples every 30 days); special samples may be sent from any weapon system when maintainers suspect contamination or impending engine, transmission or hydraulic failure.
- AR 750-1 (29 Apr 2026), para 12-2; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-2
- CMF 91: What is the difference between a scheduled service and unscheduled maintenance?
- A scheduled service (maintenance plan) is the TM- or MAM-required set of checks, adjustments and lubrication at a usage- or time-based interval (10% variance allowed). Unscheduled maintenance (fault repair) restores equipment to FMC after faults are found by PMCS, operation or breakdown. Both are recorded in GCSS-Army.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), paras 2-1a(2)-(3), 4-1c(1); AR 750-1 (29 Apr 2026), para 3-2b(6)
- CMF 91: What is a slave start, and what is the main safety concern?
- Using a NATO slave cable or approved method to start a vehicle from another vehicle's electrical system. Use the approved cable and procedures; incorrect hookup can damage electronics or cause injury. Follow the platform TM — not a civilian jumper-cable habit.
- Not independently verified – likely in restricted vehicle -10 operator TM (slave-start procedure) (CAC); check the current TM
- CMF 91: Why must you use jack stands or the TM-specified supports, not only a jack, when working under a vehicle?
- A jack is a lifting device, not a reliable support. Vehicles can slip or the jack can fail. The TM specifies approved support points and devices.
- 29 CFR 1926.600(a)(3)(i) (OSHA: equipment held aloft by jacks must be blocked or cribbed before anyone works under it); support points per the vehicle TM
- CMF 91: What is corrosion prevention and control (CPC) in Army maintenance?
- The Army CPC Program: cleaning, treating, painting and preserving equipment (operators annotate corrosion on the 5988-E and do corrective actions within their capability; unit corrosion monitors and CPC surveys support it), so corrosion does not cause faults or NMC conditions. Policy is in AR 11-42; maintenance aspects in AR 750-1 and DA Pam 750-1.
- AR 11-42 (4 May 2026); AR 750-1 (29 Apr 2026), para 12-16; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-1b(3)(b)-(c)
- CMF 91: What should a maintainer do with a fault that is not listed as NMC but is a safety problem?
- Record it, notify the supervisor, and do not ignore it. Deficiencies that render equipment NMC per the TM or violate a safety directive must be corrected before the mission; FMC equipment must also meet AR 385-10 and AR 700-138 provisions and be operable without endangering the crew.
- AR 750-1 (29 Apr 2026), para 3-9b(1); ATP 4-33 (9 Jan 2024), para 4-37
- CMF 91: What is a warranty claim on Army equipment, in brief?
- A warranty claim gets a warranted item repaired or replaced by the manufacturer/dealer or materiel developer when it fails during the warranty, instead of using unit resources. Units execute warranties per the MATDEV procedures in the warranty technical bulletin and local written instructions, coordinated through the warranty control office/coordinator.
- AR 700-139 (30 Apr 2025), paras 1-9a, 1-11; AR 750-1 (29 Apr 2026), para 2-10t
- CMF 91: How does CMF 91 relate to CMF 94 in a typical brigade?
- 91-series mechanics maintain automotive, armament, and similar mechanical systems; 94-series repairers maintain electronic, missile, radar, and other electronic systems. Both use the same maintenance levels, MAC, and GCSS-Army discipline, and both support the same combat formation.
- ATP 4-33 (9 Jan 2024), para 1-20 (two-level maintenance alignment); DA Pam 611-21 (Smartbook, Nov 2025), ch. 10 (CMF 91 and CMF 94 sections)
Keep going: more Mechanical Maintenance decks
- 91BWheeled Vehicle Mechanic222 cards
- 91HTrack Vehicle Repairer87 cards
- 91JQuartermaster and Chemical Equipment Repairer87 cards
- 91LConstruction Equipment Repairer87 cards
- 91CUtilities Equipment Repairer85 cards
- 91EAllied Trades Specialist85 cards
Not your job? Use the MOS deck finder or see every MOS deck by career field.