Drill 91C: Utilities Equipment Repairer flashcards
This page puts every 91C card in one place: 85 questions and answers for the Utilities Equipment Repairer job, spread across 3 decks.
- 85 cards
- 3 decks
- Quiz mode
How to drill 91C
- Maintenance decks have many parts and troubleshooting steps. Drill one system at a time.
- Pick one deck below and cover the answers with your hand or a sheet of paper.
- When a deck feels easy, open 91C in the app and choose Practice test. It asks multiple-choice questions built from these same cards.
With 85 cards, try about 4 short rounds of 25 cards instead of one long session. One or two rounds a day keeps it fresh.
91C decks on this page
- 91C – Deep Dive 3: Duties, HVAC/R and Support Equipment Safety, and Shop Production Control48 cards
- 91C – Utilities Equipment Repairer15 cards
- CMF 91/94 – Army Maintenance Common Knowledge22 cards
91C – Deep Dive 3: Duties, HVAC/R and Support Equipment Safety, and Shop Production Control
Source: DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91C; STP 9-91C13-SM-TG Utilities Equipment Repairer (29 Aug 2018); ATP 4-33 Maintenance Operations (9 Jan 2024), ch. 4 production control and quality paras (not used in other CMF 91 files); ATP 4-44/MCRP 3-40D.14 Water Treatment (INCL C1, 16 Sep 2025), appendix E reverse osmosis paras not used by 92W. Supplementary study aid – verify against current editions on armypubs.army.mil.
- 91C: Which fire equipment does a skill level 1 91C maintain?
- Fire extinguisher rechargers and fire extinguishers/valves.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Ca(1)
- 91C: Which other MOS's duties does a skill level 3 91C perform?
- Quartermaster and chemical equipment repairer (91J) duties.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Ca(3)
- 91C: Name equipment a skill level 3 91C inspects and troubleshoots besides HVAC.
- POL equipment, smoke generators, laundry and bath units, chemical equipment, water purification systems and portable forced-air heaters.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Ca(3)
- 91C: What management activities does a skill level 3 91C perform?
- Maintenance management, including production and quality control.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Ca(3)
- 91C: What allergy rules out 91C?
- Allergy to refrigerant gases or petroleum products.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Cb(5)
- 91C: What ASVAB scores qualify for 91C?
- GM 93, or a combination of GM 88 and GT 85.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Cb(6)(a)
- 91C: Which civilian certifications meet 91C ACASP criteria?
- The Residential and Light Commercial ICE exams plus EPA 608 (Type 1 and 2) and 609 certifications, or 2 years as an HVAC technician.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Cb(8)
- 91C: Who can waive the 91C formal training requirement?
- The Commandant, U.S. Army Ordnance School.
- DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-91Cb(7)
- 91C: What must happen before debrazing on a system that held refrigerant 22?
- Discharge all the R-22 and purge the system with dry nitrogen. Never use a heating torch on a part that contains it.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-1001 (DANGER; repeated in other HVAC/R tasks)
- 91C: What is the pressure limit for compressed air used for cleaning HVAC/R equipment?
- 30 psi.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-1001 (CAUTION; repeated in other HVAC/R tasks)
- 91C: Why must steam never be used to clean coils?
- Refrigerant lines could rupture and injure personnel.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-1001 (CAUTION)
- 91C: What size ground wire prevents shock hazard on an air conditioner?
- A 10 AWG (minimum) ground wire to the external ground.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-1001 (WARNING)
- 91C: What must you do before working on an air compressor?
- Disconnect electric power and relieve all air pressure, since it could start accidentally.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3013 (WARNING and CAUTION)
- 91C: What is the solo lifting limit in the water purification tasks?
- No more than 50 pounds by yourself.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3013 and -3014 (DANGER)
- 91C: How do you prevent drinking water contamination when working on water purification equipment?
- Cap and plug all couplings when not connected, and keep dirt, mud and sand out of open couplings.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3013 and -3014 (WARNING)
- 91C: Why remove jewelry before working on decontaminating apparatus?
- Rings and other metal objects can cause short circuits.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3007 to -3009 (DANGER)
- 91C: What PPE is needed around STB decontaminating agent?
- Protective clothing and a mask. STB and slurry harm skin, eyes, lungs and clothing.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3007 to -3009 (WARNING and CAUTION)
- 91C: Which part of the ROWPU has its own 91C diagnostic task?
- The reverse osmosis rupture disc.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3015
- 91C: What must be done after a QC/QA inspection of ground support equipment?
- Annotate all findings and corrective actions on the applicable maintenance forms.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3017
- 91C: What are the PMCS intervals in the 91C HVAC/R PMCS task?
- Before, during and after operation checks.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-1012
- 91C: Which refrigeration systems are covered in task 091-91C-1001?
- Small appliances and high-pressure systems (section 608 Type I and II), ice-making equipment and defrost systems.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-1001
- 91C: What does production control involve?
- Production planning, scheduling, and routing and rerouting work to keep all shop elements at or near capacity.
- ATP 4-33 (9 Jan 2024), para 4-59
- 91C: Who is primarily responsible for workload analysis?
- The maintenance control sergeant, who reviews new work and work in progress.
- ATP 4-33 (9 Jan 2024), para 4-60
- 91C: What does the maintenance control sergeant keep to forecast workload?
- A current operations map and an equipment density list.
- ATP 4-33 (9 Jan 2024), para 4-61
- 91C: What is a primary function of maintenance control?
- Reducing or correcting overload conditions and backlogs.
- ATP 4-33 (9 Jan 2024), para 4-66 and 4-72
- 91C: What is the maintenance control section commonly called?
- The shop office.
- ATP 4-33 (9 Jan 2024), para 4-67
- 91C: Who is normally in a maintenance control section?
- A maintenance control officer, a maintenance warrant officer, a maintenance control sergeant and an automated logistics specialist.
- ATP 4-33 (9 Jan 2024), para 4-68
- 91C: What is routing in shop production?
- The sequence of repair operations that completes each item in the shortest time.
- ATP 4-33 (9 Jan 2024), para 4-73
- 91C: What are the four production methods?
- Bay shop, job or bench shop, onsite maintenance, and production line.
- ATP 4-33 (9 Jan 2024), para 4-76
- 91C: When is the bay shop method used?
- When the shop does varied jobs or the item is hard to move. The item stays put and people and tools come to it.
- ATP 4-33 (9 Jan 2024), para 4-77
- 91C: What are job or bench shops used for?
- Small items, items needing high technical skill, or repairs with equipment mounted in a shop vehicle.
- ATP 4-33 (9 Jan 2024), para 4-78
- 91C: Name advantages of onsite maintenance.
- Less equipment downtime and no time or resources spent on recovery.
- ATP 4-33 (9 Jan 2024), para 4-79
- 91C: Which level mainly uses the production line method?
- Sustainment-level maintenance activities, for repeated repairs that split into independent steps.
- ATP 4-33 (9 Jan 2024), para 4-81
- 91C: What is the objective of quality assurance?
- To produce high-quality work the first time.
- ATP 4-33 (9 Jan 2024), para 4-82
- 91C: What are the three quality control inspections?
- Initial, in-process and final inspections. QC is a leadership function.
- ATP 4-33 (9 Jan 2024), para 4-83
- 91C: How is reverse osmosis different from filtration?
- In filtration the whole stream passes through the filter. In RO, feed flows parallel to the membrane and only part passes through, while dissolved solutes are largely rejected.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-11
- 91C: How is a reverse osmosis element built?
- Membrane sheets and mesh spacers are spirally wound around a central plastic product water collection tube with small holes.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-12
- 91C: Where does the brine go in a working RO element?
- It flows out through the feed-water spaces, collects at the end of the last element and leaves the pressure vessel.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-13
- 91C: What do anti-telescoping devices do on an RO element?
- These wagon-wheel stems form a frame that keeps the feed spacer from extending beyond the membrane leaves.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-15
- 91C: What is the leading cause of RO membrane telescoping?
- Operating the reverse osmosis purifier at excessively high pressure.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-15
- 91C: What fouls and clogs RO membranes?
- Bacterial slimes, hard water scale, iron and silt.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-17
- 91C: Name the four categories of RO membrane foulants.
- Dissolved solids, suspended solids, biological foulants and non-biological organic foulants.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-18 to E-21
- 91C: Where in an RO system does colloidal fouling start, and where does scaling start?
- Colloidal fouling starts at the first element of the first pressure vessel. Scaling starts at the end element of the last vessel and works forward.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-22
- 91C: What determines RO membrane life?
- Feed water source, pretreatment, cleaning frequency and operating conditions.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-23
- 91C: What antiscalant prevents calcium carbonate scaling in RO systems?
- Sodium hexametaphosphate, injected into the raw water.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-25
- 91C: Why rinse RO membranes with permeate before shutdown?
- To lower salt concentration and keep particulates from settling, which can foul membranes severely and often irreversibly.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-26 and E-27
- 91C: What should be used if RO membranes will sit idle for a long time?
- An appropriate preservative to inhibit biological growth.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-27
- 91C: Which cleaning step do membrane makers usually recommend first?
- Alkaline cleaning. Acid goes first only when scaling alone is known to be present.
- ATP 4-44/MCRP 3-40D.14 (INCL C1, 16 Sep 2025), para E-28
91C – Utilities Equipment Repairer
Source: DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91C), table 10-1; AR 750-1 (29 Apr 2026); DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026) (DA Pam 750-8 inactive on APD; see DA Pam 750-1 (29 Apr 2026)); ATP 4-33 (9 Jan 2024); goordnance.army.mil (Ordnance School training locations); STP 9-91C13-SM-TG (29 Aug 2018); 40 CFR 82 subpart F (refrigerant management). Equipment TMs are mostly distribution-restricted – verify in the current TM.
- 91C: What is the primary role of the Utilities Equipment Repairer?
- Status: current MOS (DA Pam 611-21 ch. 10C). Supervises and performs field-level maintenance on utilities equipment and special purpose support systems – air conditioners/environmental control units, refrigeration units, portable heaters, and fire extinguishers and fire extinguisher rechargers. At SL3, 91Cs also perform 91J (quartermaster and chemical equipment) duties.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91C, para a(1)-(3))
- 91C: What is an ECU?
- Environmental Control Unit – military air conditioning/heating unit for shelters and equipment.
- STP 9-91C13-SM-TG (29 Aug 2018), ch. 3 (HVAC/R tasks, e.g., 091-91C-1001, -1012); DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91C para a(1): air conditioner systems)
- 91C: What certification is required to handle refrigerants?
- EPA Section 608 technician certification.
- 40 CFR 82.161(a) (technician certification); STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-1001 (section 608 Type I and II systems)
- 91C: What is the refrigeration cycle?
- Compression, condensation, expansion, and evaporation of refrigerant to move heat.
- Unofficial – common unit practice/SOP; not found in official doctrine
- 91C: What environmental rule applies to refrigerants?
- Refrigerants must be recovered, not vented, under the Clean Air Act.
- 40 CFR 82.154(a)(1) (venting prohibition, Clean Air Act sec. 608 regulations); STP 9-91C13-SM-TG (29 Aug 2018), tasks 091-91C-1010, -3003 (refrigerant recovery/recycling equipment)
- 91C: Where is 91C AIT?
- 91C training is conducted under the auspices of the U.S. Army Ordnance School; the Ordnance School lists 91C training at Fort Lee, VA (formerly Fort Gregg-Adams) – verify current course length with your recruiter/ATRRS.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91C, para b, formal training); goordnance.army.mil/schools/VA_lee.html (Ordnance training location – Fort Lee, VA; retrieved 22 Nov 2026); HQDA GO 2025-16 (Fort Gregg-Adams redesignated Fort Lee, 11 Jun 2025)
- 91C: Where do 91Cs work?
- Maintenance companies and support units that sustain environmental control units, refrigeration, and field heaters.
- ATP 4-33 (9 Jan 2024), paras 2-41 (support maintenance company), 2-67 (field maintenance company), 2-73 (FSC)
- 91C: What is a refrigerant leak check?
- Using an electronic leak detector or soap solution to find refrigerant leaks.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-3003 (inspect, repair/replace and test the system for leaks); detection methods: Unofficial – common unit practice/SOP; not found in official doctrine
- 91C: What is a vacuum pump used for in HVAC repair?
- Removing air and moisture from a refrigeration system before charging it.
- Unofficial – common unit practice/SOP; not found in official doctrine
- 91C: What is "superheat"?
- How many degrees refrigerant vapor is heated above its saturation (boiling) temperature at that pressure; measured at the evaporator outlet to judge charge and evaporator performance.
- Unofficial – common unit practice/SOP; not found in official doctrine
- 91C: What field heaters might 91Cs repair?
- Space heaters for tents and shelters used in cold weather operations.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91C para a(1): portable heater fuel/electrical systems); STP 9-91C13-SM-TG (29 Aug 2018), tasks 091-91C-3004, -3009 (heater fuel systems, heating systems)
- 91C: What are the basic components of a refrigeration system?
- Compressor, condenser, expansion device, and evaporator.
- STP 9-91C13-SM-TG (29 Aug 2018), tasks 091-91C-1003 (condenser/evaporator coil components), -1007/-1008 (compressor)
- 91C: What electrical hazards exist in ECU repair?
- Line voltage, capacitors that retain charge, and motor circuits – de-energize and discharge before work.
- STP 9-91C13-SM-TG (29 Aug 2018), task 091-91C-1001 DANGER (lethal voltages; ground capacitors before touching)
- 91C: What are refrigerated containers used for in the Army?
- Storing perishable food and medical supplies; 91Cs maintain refrigeration units.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-91C para a(1): refrigeration unit electrical systems); storage uses: Unofficial – common unit practice/SOP; not found in official doctrine
- 91C: What is the skill progression for 91C?
- SL1 repairer (E-3/E-4); SL2 team leader/supervisor (SGT); SL3 section/shop sergeant (SSG) – 91C is graded E-3 to E-6. At SFC, 91C Soldiers move to 91X Maintenance Supervisor, then 91Z (MSG/SGM). At SL3, 91Cs also perform 91J duties.
- DA Pam 611-21 (Oct 2026 copy), Fig 10-1, table 10-1; ch. 10C (10-91C para a(1)-(3); 10-91X para b(6); 10-91Z para b(3))
CMF 91/94 – Army Maintenance Common Knowledge
Source: AR 750-1 (29 Apr 2026), Army Materiel Maintenance Policy; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), Army Materiel Maintenance Procedures (replaces DA Pam 750-8, inactive on APD TAMMS forms/procedures); ATP 4-33 (9 Jan 2024), Maintenance Operations; DA Pam 25-40 (1 Feb 2024) (TM numbering); AR 700-139 (30 Apr 2025); AR 11-42 (4 May 2026); DA Pam 611-21 (Smartbook, Nov 2025), ch. 10 (CMF 91/94); 29 CFR 1910 (OSHA). Applies to 91- and 94-series maintainers.
- CMF 91: What are the TM "dash numbers" and what do they mean?
- Level-of-maintenance numbers: -10 operator/crew; -12 operator through maintainer; -20 maintainer (field) maintenance. Suffix "P" = a separately published repair parts and special tools list (RPSTL), e.g., -20P; "&P" = RPSTL included in the same TM (e.g., -20&P). Older multi-level numbers such as -23/-24 still appear on legacy TMs.
- DA Pam 25-40 (1 Feb 2024), para 8-26d and f, table 8-5; ATP 4-33 (9 Jan 2024), app C, para C-2 (legacy TMs not yet converted to two-level)
- CMF 91: What is the Maintenance Allocation Chart (MAC)?
- The TM section that designates authority and responsibility for performing maintenance functions on an item. Field maintenance may perform tasks coded C, O and F; sustainment adds H, and depot/AMC-designated activities L and D, when skilled maintainers, tools and TMDE are available.
- ATP 4-33 (9 Jan 2024), app C, paras C-1, C-3, C-4; AR 750-1 (29 Apr 2026), para 3-8b
- CMF 91: What is the Army maintenance standard (TM 10/20 standard)?
- One mandatory standard, defined by the TM-10 and TM-20 series. Equipment meets it when all nine conditions exist: (1) it is FMC; (2) all faults are identified at the prescribed intervals using the PMCS "items to be checked" column; (3) all field-level repairs and services for which parts are available are done; (4) parts not on hand are requisitioned per AR 710-2; (5) work the MAC does not authorize at field level goes to sustainment with turn-in documentation; (6) scheduled services are done at the TM/MAM interval (10% variance allowed; past it the item is NMC); (7) MWOs, safety-of-use and other maintenance messages are applied and recorded in the MMIS; (8) all authorized BII and COEI are present and serviceable or on valid requisition; (9) maintenance advisory/information messages directing software updates are applied and reported in the MMIS.
- AR 750-1 (29 Apr 2026), para 3-2a and b(1)-(9)
- CMF 91: What does FMC, PMC, and NMC mean?
- Fully Mission Capable (safe, all mission-essential subsystems operating; no "not FMC ready if" faults); Partially Mission Capable (can perform at least one but not all missions – AR 750-1 defines PMC for aircraft and training devices); Not Mission Capable (cannot perform any one of its combat missions; split into NMC-maintenance and NMC-supply).
- AR 750-1 (29 Apr 2026), glossary (FMC, NMC, NMC-M, NMC-S, PMC); ATP 4-33 (9 Jan 2024), paras 4-37, 4-38
- CMF 91: What is a QDR?
- Product Quality Deficiency Report (PQDR) – reports deficient (e.g., defective new) parts or materiel. PQDRs and EIRs are submitted through the Product Data Reporting and Evaluation Program (PDREP) or on SF 368; instructions are in DA Pam 738-751.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-7a; AR 750-1 (29 Apr 2026), para 2-12n
- CMF 91: What is an EIR?
- Equipment Improvement Recommendation – reports a design, operation or maintenance-instruction shortcoming so it can be evaluated for changes. Filed with PQDRs through PDREP or on SF 368 (DA Pam 738-751).
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-7a
- CMF 91: What is "cannibalization," and is it allowed?
- Cannibalization is removing serviceable parts from unserviceable, generally uneconomically repairable, items; it is permitted only where authorized (e.g., authorized cannibalization points under AR 710-2/DA Pam 710-2-2, or limited cases before turn-in to DLA Disposition Services). Controlled exchange is different: removing serviceable parts from unserviceable but economically repairable end items for immediate reuse, allowed only under AR 750-1 para 4-11 conditions (part not available within the IPD, valid requisition submitted, donor NMC-S, removal recorded on the 5990-E/5988-E).
- AR 750-1 (29 Apr 2026), paras 4-11, 8-10a, 9-2b; glossary (Cannibalization – see DoDI 4151.18); DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 5-1 (operation of cannibalization points when authorized)
- CMF 91: What is a maintenance meeting?
- A recurring command meeting reviewing equipment status, parts on order, services due, and maintenance priorities.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-26d (MCO reviews and communicates maintenance status through maintenance meetings)
- CMF 91: What is the 91X MOS?
- Maintenance Supervisor (SFC, MOSC 91X4O). Soldiers come from the 91B, 91C, 91D, 91E, 91F, 91H and 91L courses. 91A, 91M, 91P and 91S have their own SL4 and, with 91X, feed 91Z (MSG/SGM; titled Mechanical Maintenance Supervisor in table 10-1, Senior Maintenance Supervisor in 10C).
- DA Pam 611-21 (Smartbook, Nov 2025), table 10-1; ch. 10C (10-91X, para b(6); 10-91Z, para b(3))
- CMF 91: What is the 94W MOS?
- Electronic Maintenance Supervisor (SFC); 94Z Senior Electronic Maintenance Supervisor at MSG/SGM.
- DA Pam 611-21 (Smartbook, Nov 2025), table 10-1 (94W4 E7; 94Z5/94Z6 E8-E9)
- CMF 91: What is lockout/tagout?
- Isolating energy sources (electrical, hydraulic, pneumatic) and tagging them so equipment cannot be energized during maintenance.
- 29 CFR 1910.147 (Control of hazardous energy), para (a)(1)(i)
- CMF 91: What is an SDS?
- Safety Data Sheet – hazards, handling, PPE, and first aid for a hazardous material.
- 29 CFR 1910.1200 (Hazard Communication), para (g)
- CMF 91: What is a DA Form 5988-E (or the current equivalent equipment fault form)?
- DA Form 5988-E, Equipment Maintenance and Inspection Worksheet (EGA), produced from GCSS-Army: operators record PMCS faults and corrosion on it, and maintainers use it to document and correct them. Equipment with uncorrected NMC or safety-directive faults found in before-operations PMCS must not be dispatched until fixed. DA Pam 750-8 is inactive on APD; the form is now prescribed in DA Pam 750-1.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-1b(3)(c) and app A; AR 750-1 (29 Apr 2026), para 3-9b(1)
- CMF 91: What is dispatch, in maintenance terms?
- The controlled release of equipment for use: the commander designates a school-trained ERPS clerk to manage dispatch, which confirms the operator is qualified and PMCS is done to the maintenance standard, and records use on DA Form 5987-E (or 5987-1-E/DD 1970; DA Form 2401 only when automated dispatch is not possible). A normal dispatch is signed by the company commander or designated representative for up to 7 days.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-5e and f(1)
- CMF 91: What is AOAP?
- The Army Oil Analysis Program – lab analysis of component lubricants to support data-driven maintenance. Under AR 750-1 (2026) routine AOAP sampling applies only to Aviation Ground Support Equipment (hydraulic samples every 30 days); special samples may be sent from any weapon system when maintainers suspect contamination or impending engine, transmission or hydraulic failure.
- AR 750-1 (29 Apr 2026), para 12-2; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 9-2
- CMF 91: What is the difference between a scheduled service and unscheduled maintenance?
- A scheduled service (maintenance plan) is the TM- or MAM-required set of checks, adjustments and lubrication at a usage- or time-based interval (10% variance allowed). Unscheduled maintenance (fault repair) restores equipment to FMC after faults are found by PMCS, operation or breakdown. Both are recorded in GCSS-Army.
- DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), paras 2-1a(2)-(3), 4-1c(1); AR 750-1 (29 Apr 2026), para 3-2b(6)
- CMF 91: What is a slave start, and what is the main safety concern?
- Using a NATO slave cable or approved method to start a vehicle from another vehicle's electrical system. Use the approved cable and procedures; incorrect hookup can damage electronics or cause injury. Follow the platform TM — not a civilian jumper-cable habit.
- Not independently verified – likely in restricted vehicle -10 operator TM (slave-start procedure) (CAC); check the current TM
- CMF 91: Why must you use jack stands or the TM-specified supports, not only a jack, when working under a vehicle?
- A jack is a lifting device, not a reliable support. Vehicles can slip or the jack can fail. The TM specifies approved support points and devices.
- 29 CFR 1926.600(a)(3)(i) (OSHA: equipment held aloft by jacks must be blocked or cribbed before anyone works under it); support points per the vehicle TM
- CMF 91: What is corrosion prevention and control (CPC) in Army maintenance?
- The Army CPC Program: cleaning, treating, painting and preserving equipment (operators annotate corrosion on the 5988-E and do corrective actions within their capability; unit corrosion monitors and CPC surveys support it), so corrosion does not cause faults or NMC conditions. Policy is in AR 11-42; maintenance aspects in AR 750-1 and DA Pam 750-1.
- AR 11-42 (4 May 2026); AR 750-1 (29 Apr 2026), para 12-16; DA Pam 750-1 (29 Apr 2026, incl. admin revisions through 19 Oct 2026), para 4-1b(3)(b)-(c)
- CMF 91: What should a maintainer do with a fault that is not listed as NMC but is a safety problem?
- Record it, notify the supervisor, and do not ignore it. Deficiencies that render equipment NMC per the TM or violate a safety directive must be corrected before the mission; FMC equipment must also meet AR 385-10 and AR 700-138 provisions and be operable without endangering the crew.
- AR 750-1 (29 Apr 2026), para 3-9b(1); ATP 4-33 (9 Jan 2024), para 4-37
- CMF 91: What is a warranty claim on Army equipment, in brief?
- A warranty claim gets a warranted item repaired or replaced by the manufacturer/dealer or materiel developer when it fails during the warranty, instead of using unit resources. Units execute warranties per the MATDEV procedures in the warranty technical bulletin and local written instructions, coordinated through the warranty control office/coordinator.
- AR 700-139 (30 Apr 2025), paras 1-9a, 1-11; AR 750-1 (29 Apr 2026), para 2-10t
- CMF 91: How does CMF 91 relate to CMF 94 in a typical brigade?
- 91-series mechanics maintain automotive, armament, and similar mechanical systems; 94-series repairers maintain electronic, missile, radar, and other electronic systems. Both use the same maintenance levels, MAC, and GCSS-Army discipline, and both support the same combat formation.
- ATP 4-33 (9 Jan 2024), para 1-20 (two-level maintenance alignment); DA Pam 611-21 (Smartbook, Nov 2025), ch. 10 (CMF 91 and CMF 94 sections)
Keep going: more Mechanical Maintenance decks
- 91BWheeled Vehicle Mechanic222 cards
- 91DPower-Generation Equipment Repairer87 cards
- 91HTrack Vehicle Repairer87 cards
- 91JQuartermaster and Chemical Equipment Repairer87 cards
- 91LConstruction Equipment Repairer87 cards
- 91EAllied Trades Specialist85 cards
Not your job? Use the MOS deck finder or see every MOS deck by career field.