12K flashcard drill: Plumber
Want to know your 12K material cold? Start here. There are 176 flashcards for the Plumber job, and the biggest deck, “Deep Dive: Duties, Water Distribution & Sewerage Basics,” has 80 cards.
- 176 cards
- 4 decks
- Quiz mode
How to drill 12K
- Pick one deck below and cover the answers with your hand or a sheet of paper.
- Engineer decks mix materials, measurements and safety rules. Keep scrap paper close and work out any numbers before you check the answer.
- When a deck feels easy, open 12K in the app and choose Practice test. It asks multiple-choice questions built from these same cards.
With 176 cards, try about 8 short rounds of 25 cards instead of one long session. One or two rounds a day keeps it fresh.
12K decks on this page
- 12K – Deep Dive: Duties, Water Distribution & Sewerage Basics80 cards
- 12K – Deep Dive: Pipes, Valves, Stacks, Traps, Vents, Gas Piping & Pumps80 cards
- 12K – Thin Section: Electrical & Electronics (Electrically Cooled Fountain)1 card
- 12K – Plumber15 cards
12K – Deep Dive: Duties, Water Distribution & Sewerage Basics
Source: DA Pam 611-21 ch. 10C (10-12K, Oct 2026 copy); TM 3-34.70 (Plumbing, Pipe Fitting and Sewerage, 23 Jul 2012). Complements mos-12k-plumber; does not repeat those cards. Verify current editions.
- 12K deep dive: Is 12K an Army Civilian Acquired Skills Program (ACASP) designated MOS?
- Yes. MOS 12K is an ACASP designated MOS.
- DA Pam 611-21 (ch. 10C, Oct 2026 copy), 10-12K heading
- 12K deep dive: Besides installing pipe and fixtures, what other duties does DA Pam 611-21 list for a 12K1O?
- A 12K1O repairs valves and fixture-control devices and steel, plastic, copper, cast-iron, and PEX pipe; maintains plumbing tools; grades sewer lines; tests waste and water systems; clears waste-system stoppages; identifies plumbing materials; winterizes water systems; interprets plumbing prints and drawings; prepares a material takeoff list; and rescues an electrical-shock victim.
- DA Pam 611-21 (ch. 10C, Oct 2026 copy), 10-12K a(1)
- 12K deep dive: What duties does DA Pam 611-21 list for a 12K2O?
- A 12K2O installs cast-iron pipes and draws a plumbing job plan, coordinates construction planning and advises on plumbing construction, inspects plumbing systems and components for proper installation, and ensures proper safety procedures are used.
- DA Pam 611-21 (ch. 10C, Oct 2026 copy), 10-12K a(2)
- 12K deep dive: What minimum Occupational Physical Assessment Test (OPAT) scores does DA Pam 611-21 require for 12K?
- Standing Long Jump 120 cm, seated Power Throw 350 cm, Strength Deadlift 120 pounds, and Interval Aerobic Run 36 shuttles, in Physical Demand Category “Moderate” (Gold).
- DA Pam 611-21 (ch. 10C, Oct 2026 copy), 10-12K b(4)(b)
- 12K deep dive: Why must a 12K be free from vertigo?
- Freedom from vertigo is required to permit climbing, balancing, and working in high places.
- DA Pam 611-21 (ch. 10C, Oct 2026 copy), 10-12K b(5)
- 12K deep dive: What civilian experience does DA Pam 611-21 require for 12K ACASP qualification?
- A minimum of 2 years experience as an apprenticed member of a recognized United States plumber association.
- DA Pam 611-21 (ch. 10C, Oct 2026 copy), 10-12K b(7)
- 12K deep dive: Does a Soldier who qualifies for 12K under ACASP have to attend AIT?
- No. An Initial Entry Trainee (IET) who qualifies under ACASP will not be required to attend AIT. After Basic Combat Training, the Soldier is processed in accordance with initial assignment instructions.
- DA Pam 611-21 (ch. 10C, Oct 2026 copy), 10-12K b(7)(a)
- 12K deep dive: Who approves and validates 12K ACASP qualification for an Initial Entry Trainee?
- The USAES Engineer Personnel Development Office (EPDO).
- DA Pam 611-21 (ch. 10C, Oct 2026 copy), 10-12K b(7)(b)
- 12K deep dive: What water-pressure range is usual in the main, and what must a 12K do if the pressure is too high or too low?
- Pressure in the main usually ranges from 45 to 60 psi. If it is over 60 psi, a pressure-reducing valve must be placed in the water service line at the building entry. If it is less than 15 psi, use a tank and a pump or other means to provide pressure. If it is over 80 psi, use an approved pressure regulator.
- TM 3-34.70 (23 Jul 2012), para 1-15
- 12K deep dive: What is the minimum practical size for a water service line?
- 3/4 inch. Use that size even when calculations indicate a smaller one.
- TM 3-34.70 (23 Jul 2012), para 1-16
- 12K deep dive: What is friction loss in a water-supply pipe, and how can a plumber reduce it?
- Layers of liquid move at different speeds, with the center layer moving fastest. That resistance to flow is friction loss, and it causes a drop in water pressure. In a small pipe, increase the water pressure to overcome it; if higher pressure is not possible, increase the pipe size.
- TM 3-34.70 (23 Jul 2012), para 1-11
- 12K deep dive: What is water hammer, and when can it occur?
- Water hammer occurs when flowing water is stopped abruptly or cannot be compressed, so the water slams against the valve with the same pressure as the water system—for example, when a water-closet tank finishes filling and the control valve in the tank closes.
- TM 3-34.70 (23 Jul 2012), para 1-12
- 12K deep dive: How does an expansion chamber stop water hammer, and where should it be installed?
- The chamber is capped at the upper end so it fills with air, not water. Air can be compressed, so it works like a shock absorber when flow is stopped abruptly. Install expansion chambers on both the hot and cold service lines at each major fixture in the structure.
- TM 3-34.70 (23 Jul 2012), para 1-13
- 12K deep dive: When fabricating an expansion chamber, how long must the riser section be?
- The type of pipe and the dimensions are not critical, but the section identified as the riser must be at least 6 inches long.
- TM 3-34.70 (23 Jul 2012), para 1-14
- 12K deep dive: What fixture-demand values in gallons per minute does TM 3-34.70 list for common fixtures?
- Water closet 45.0, lavatory 7.5, shower 15.0, urinal 39.5, slop sink 22.5, laundry tub 15.0, and floor drain 7.5 gallons per minute.
- TM 3-34.70 (23 Jul 2012), para 1-17, table 1-1
- 12K deep dive: If a simultaneous-use-factor table is not available, how should probable demand be estimated?
- Compute 30 percent of the maximum fixture demand in gallons.
- TM 3-34.70 (23 Jul 2012), para 1-21
- 12K deep dive: Where should gate valves be installed in a water-supply system?
- Install gate valves in each vertical supply riser so a section can be repaired without shutting off water to other sections. Small gate valves on the supply to each fixture allow the water to be shut off for faucet repairs.
- TM 3-34.70 (23 Jul 2012), para 1-26
- 12K deep dive: How and when should a new water-supply system be tested for leaks?
- In new construction, test the entire system for leaks before the floor and partitions are closed up. Use the water pressure from the main that feeds the system, and inspect each joint for moisture while the system is under pressure.
- TM 3-34.70 (23 Jul 2012), para 1-27
- 12K deep dive: After installing or repairing drinking-water piping, what must a plumber do before the system is used?
- Clean and disinfect the plumbing pipes and other parts that carry drinking water. Flush the system to remove dirt, waste, and surface water, then disinfect each unit with a chemical such as a hypochlorite or chlorine solution.
- TM 3-34.70 (23 Jul 2012), para 1-28
- 12K deep dive: What temperature freezes water-supply lines, and how deep should outside pipes be buried?
- Water-supply lines may freeze below 32 degrees Fahrenheit. Outside pipes must be buried below the frost line; in northern zones this is 4 feet or more. If the building temperature falls below freezing, inside pipes may also freeze and break at the weakest point.
- TM 3-34.70 (23 Jul 2012), para 1-33
- 12K deep dive: What is galvanic corrosion in a plumbing system?
- Galvanic corrosion, resulting from a direct current of electricity, occurs in a plumbing system that includes two different kinds of metal pipe, such as galvanized pipe and copper pipe.
- TM 3-34.70 (23 Jul 2012), para 1-31
- 12K deep dive: What do curb and meter stops control, and where is the curb stop usually set?
- Curb and meter stops control the water entering the building. After the water main is tapped and the corporation stop is inserted, the curb stop is usually set in a cast-iron stop box to provide easy access in the water service between the curb and the building.
- TM 3-34.70 (23 Jul 2012), paras 1-35 and 1-36
- 12K deep dive: What is a meter stop, and where should it be placed?
- The meter stop is a ground-joint valve that controls and shuts off the flow of water into the building. Place it as close to the service-pipe entry as possible. The water meter is installed near the meter stop and measures the amount of water used in the building.
- TM 3-34.70 (23 Jul 2012), paras 1-39 and 1-40
- 12K deep dive: What slope should a house sewer have when possible, and how can that grade be checked with a carpenter’s level?
- When possible, grade house sewers to 1/4 inch per foot; a greater or lesser slope is permitted when necessary. For a 1/4-inch-per-foot slope, use a 2-foot carpenter’s level with a 1/2-inch-thick board under one end. If the pipe is sloped correctly, the level will read level anywhere on the pipe except the hub. Grade the drain toward the main sewer with the hub end of the pipe lying upgrade.
- TM 3-34.70 (23 Jul 2012), para 1-78
- 12K deep dive: How far must underground plumbing be kept from underground electrical cable?
- All underground plumbing must be laid at least 12 inches from any underground electrical cable. Failure to do so could result in physical injury, death, and/or destruction of equipment.
- TM 3-34.70 (23 Jul 2012), para 1-78 (DANGER)
- 12K deep dive: How should the main water-supply pipe be laid out, graded, and drained for winter?
- The main supply has the same diameter as the water service from the main and should be laid as straight as possible to reduce friction loss. It must not sag or trap water. Grade it slightly, up to 1/4 inch per foot, dropping toward the water meter. At the low end, place a drip cock or stop-and-waste valve to drain the pipe in winter. Any parts that cannot be drained from that point need their own drip cocks or stop-and-waste valves, and the pipe must be well supported so its weight is not on the fittings.
- TM 3-34.70 (23 Jul 2012), para 1-24
- 12K deep dive: What is hard water, and what problem does it cause in plumbing?
- Hard water contains a large amount of calcium and magnesium compounds, which prevent soap from lathering. This forms a scum that slows the flow of water. The scum deposits harden and form scale.
- TM 3-34.70 (23 Jul 2012), para 1-32
- 12K deep dive: What size are water mains usually, and how large may a tap be if the main is smaller than that?
- Water mains are usually cast iron, 8 inches or more in diameter. If the main is less than 8 inches in diameter, taps should be 2 inches or smaller.
- TM 3-34.70 (23 Jul 2012), para 1-34
- 12K deep dive: Why is a two-pipe circulating hot-water system used instead of a one-pipe system in a large or multi-story building?
- In a one-pipe system there is a lag from the time the hot-water tap is opened until the water travels from the heater to the tap. A two-pipe circulating system loops hot water from the heater through the fixture supply risers and back to the heater, so the water in the loop stays hot and hot water is available as soon as a tap is opened.
- TM 3-34.70 (23 Jul 2012), paras 1-47 and 1-48
- 12K deep dive: How far from a fire-resistant building should fire hydrants usually be located?
- Fire hydrants are usually located at least 50 feet from each building or from the water distribution system within the building.
- TM 3-34.70 (23 Jul 2012), para 1-51
- 12K deep dive: What is the difference between the building drain, the house drain, and the house sewer?
- The building drain receives sanitary and domestic wastes from within the building. The house drain, also called the collection line, is between the building drain and the house sewer and may be underground or hung from the basement ceiling. The house sewer begins just outside the building foundation wall and ends at the main sewer in the street or at a septic tank.
- TM 3-34.70 (23 Jul 2012), paras 1-59, 1-60, and 1-61
- 12K deep dive: Why must sanitary sewers not be connected to storm sewers, and what does a storm sewer carry?
- Sanitary discharge must be treated before it is dumped into a stream or lake, so sanitary sewers are not connected to storm sewers. A storm sewer carries rainwater and subsurface water only; because that discharge is runoff, treatment is not needed.
- TM 3-34.70 (23 Jul 2012), paras 1-61 and 1-62
- 12K deep dive: What pipe is usually used for house sewers and drains, and what may be substituted for the house sewer when it is not prohibited?
- Cast-iron soil pipe or plastic pipe is usually used for house sewers and drains. When it is not prohibited, bituminous-fiber pipe may be substituted for cast-iron pipe for the house sewer. Concrete or vitrified-clay pipe is found in older installations.
- TM 3-34.70 (23 Jul 2012), para 1-65
- 12K deep dive: How is hub-and-spigot cast-iron soil pipe different from hubless pipe?
- Hub-and-spigot pipe comes in 5- and 10-foot lengths and is connected with lead, oakum, or mechanical compression joints. Hubless pipe comes in 10-foot lengths and is connected with a stainless-steel band over a neoprene sleeve.
- TM 3-34.70 (23 Jul 2012), para 1-67
- 12K deep dive: What is ABS pipe used for, and how is it joined?
- Acrylonitrile butadiene-styrene (ABS) is gray or black plastic pipe used for storm or sanitary drainage, above and below ground. It is connected with solvent-cement joints and comes in 10- and 20-foot lengths in various diameters.
- TM 3-34.70 (23 Jul 2012), para 1-68
- 12K deep dive: How full should a house drain or house sewer flow under normal use, and why?
- Size the pipe to flow half full under normal use. Then it will have good scouring action and can still carry peak loads when required. The pipe must be large enough to carry all the water and waste, but small enough for the water to move rapidly and force the waste through to the sewer.
- TM 3-34.70 (23 Jul 2012), para 1-70
- 12K deep dive: What is a drainage fixture unit (DFU), and what DFU values does TM 3-34.70 list for common fixtures?
- One DFU represents approximately 7.5 gallons of water being discharged per minute. The listed values are lavatory or washbasin 1; floor drain, kitchen sink, bathtub, laundry tub, and shower 2 each; slop sink 3; and urinal and water closet 6 each.
- TM 3-34.70 (23 Jul 2012), para 1-71, table 1-5
- 12K deep dive: What support is required under house sewer and drain piping?
- A base of solid, undisturbed earth is enough support and helps prevent settling that could overload the joints. If the soil is loose, each joint should be supported on concrete, cinder block, or brick.
- TM 3-34.70 (23 Jul 2012), para 1-76
- 12K deep dive: How should a sewer thimble be placed when connecting a house sewer to the main sewer?
- Connect the sewer thimble first and work back, grading up to the house drain. Cut the hole no larger than needed to fit the thimble, and tap the thimble in above the normal flow level. For example, if the street sewer is 24 inches in diameter and normal flow is 50 percent, the tap should be at least 12 inches above the bottom of the pipe. Install the thimble with its discharge parallel to the direction of sewer flow to prevent backflow during high flow, and pack a rich portland-cement mortar (one part sand to one part cement) around the thimble.
- TM 3-34.70 (23 Jul 2012), para 1-77
- 12K deep dive: What is a sewer manhole used for?
- Manholes are entranceways to the sewer system for cleaning, inspection, and repair. They are round, constructed of cement with brick-and-mortar walls on a concrete slab, and closed at the top by a removable heavy lid in a cast-iron ring. Precast concrete manholes are available, but the military plumber rarely installs that type.
- TM 3-34.70 (23 Jul 2012), para 1-79
- 12K deep dive: Where should a grease trap be placed, and how do baffle walls work?
- Grease traps are placed in the flow line of the building’s sewer system to catch grease and fats from kitchen and scullery sinks, because solid grease usually clogs the waste pipes. Set the trap in the waste line as close as possible to the fixture. Baffle walls in the box control the flow and separate floating grease particles.
- TM 3-34.70 (23 Jul 2012), para 1-80
- 12K deep dive: What is a septic tank designed to do, and how long must it hold sewage?
- A septic tank speeds up the decay of raw sewage and should be watertight. It must be designed to hold, for 24 hours and not less than 16 hours, 70 percent of the peak water demand of that facility. It should have a manhole and cover for cleaning and repair.
- TM 3-34.70 (23 Jul 2012), para 1-81
- 12K deep dive: How is a soil percolation test performed for a drainage bed?
- Dig at least six test holes, 1 foot square, to the depth of the planned drainage bed. Place a 2-inch layer of gravel in the bottom and fill the holes with water. If the soil is tight or has a heavy clay content, let the holes stand overnight; sandy soil that loses water rapidly needs no soaking period. Pour water to a depth of 6 inches above the gravel, then measure the water every 10 minutes over a 30-minute period. Use the drop in the final 10 minutes to find the percolation rate.
- TM 3-34.70 (23 Jul 2012), para 1-90
- 12K deep dive: When is soil unsuitable for a subsurface-drainage system, according to the percolation test?
- Soil that takes 30 minutes to absorb 1 inch of water needs 4 feet of drainage for each gallon of liquid. If a test hole needs more than 30 minutes to absorb 1 inch of water, the soil is not suitable for a subsurface-drainage system.
- TM 3-34.70 (23 Jul 2012), para 1-90
- 12K deep dive: How far must field latrines be from a dining facility and from the nearest water source?
- Latrines should be at least 100 yards from the dining facility and 100 feet from the nearest water source. They should not be dug below the groundwater table or where they may drain into a water source. They are usually built at least 30 yards from the end of the unit area, but within a reasonable distance for easy access.
- TM 3-34.70 (23 Jul 2012), para 1-127
- 12K deep dive: What size and slope of plastic pipe is usually enough to carry wastewater from a theater-of-operations facility to a disposal system?
- For most theater construction, a 6- to 12-inch plastic pipe is sufficient. Place the pipe at about a 2 percent slope to allow gravity feed. Pipe size by flow rate is less than 300 gallons per minute, 6 inches; 300 to 700, 8 inches; 700 to 1,250, 10 inches; and 1,250 to 2,200, 12 inches.
- TM 3-34.70 (23 Jul 2012), para 1-191, table 1-12
- 12K deep dive: What is the minimum cover for wastewater pipe?
- In areas where freezing temperatures occur, the pipes must be placed below the frost line, except for subsurface tile systems. Minimum cover is 6 inches in pedestrian areas, 24 inches for light vehicles, and 48 inches for heavy vehicles (2 1/2 tons and greater).
- TM 3-34.70 (23 Jul 2012), para 1-192
- 12K deep dive: What is pipe corrosion, and what two methods reduce it in a plumbing system?
- Pipe corrosion is the thinning of the wall of a metal pipe, caused by electrolysis (chemical breakdown by electric current), rust, or acidity of the water. The two ways to reduce corrosion are dielectric unions and magnesium rods. A dielectric union has a fiber washer that insulates a water tank from the rest of the system so current cannot flow from the tank. Magnesium rods in some water heaters act as electrolytic cells; 18 months is considered their maximum life, and then they must be replaced.
- TM 3-34.70 (23 Jul 2012), paras 3-1 and 3-4
- 12K deep dive: What must a plumber do before making a temporary repair to a small leak, and what materials can be used?
- Shut off the water and relieve the pressure from the system. Temporary repairs can be made with rubber hose or plastic tubing and hose clamps, sheet rubber and sheet-metal clamps, several layers of electrician's friction tape extending about 2 inches above and below the leak, or a wood plug driven into a small hole (the plug swells as it absorbs water). Make a permanent repair as soon as possible, using a unit of the same size and quality as the original.
- TM 3-34.70 (23 Jul 2012), para 3-7
- 12K deep dive: How should a plumber thaw an aboveground frozen pipe with a blowtorch?
- A blowtorch is the best method to thaw aboveground pipes, but there is a risk of fire. Open the faucets in the line, apply heat at one end of the pipe and work along its entire length, and continue until the water flows freely. Do not overheat; solder joints will break loose when the solder melts.
- TM 3-34.70 (23 Jul 2012), para 3-9
- 12K deep dive: Besides a blowtorch, how else can aboveground frozen pipes be thawed?
- Pipes can be thawed by wrapping them with burlap or other cloth and pouring boiling water over the wrappings, which transmits heat to the frozen pipe. If internal freezing is due to failure of the heating plant, repair the heating plant and keep a high temperature in the building until the pipes thaw.
- TM 3-34.70 (23 Jul 2012), paras 3-10 and 3-11
- 12K deep dive: How should a plumber thaw a frozen underground pipe?
- Remove the pipe fittings and place a small thaw pipe or tube into the frozen pipe. Add an elbow and a piece of vertical pipe to the outer end, put a bucket under the opening, and pour boiling water into a funnel in the vertical pipe, pushing the thaw pipe forward as the ice melts. After flow starts, withdraw the thaw pipe quickly and let the flow continue until the thaw pipe is completely withdrawn and cleared of ice. A small pump may be used, but monitor it carefully because excessive pump pressure can cause a backup.
- TM 3-34.70 (23 Jul 2012), para 3-12
- 12K deep dive: How can scum or scale be removed from the inside of a pipe, and when should chemical cleaners not be used?
- Flush with hot water; use lye, or lye mixed with a small quantity of aluminum shavings (only cold water should be used with lye); or replace the entire pipe when flow is sharply reduced. Chemical cleaners should not be used in pipes that are completely stopped up, because the cleaners must contact the stoppage directly.
- TM 3-34.70 (23 Jul 2012), para 3-15
- 12K deep dive: Where can a waste-system stoppage occur, and what usually causes it?
- A stoppage can occur in a fixture drain, floor drain, branch line, or main line. The cause can be hair, grease, or other foreign matter that holds back the flow of waste. Use the proper clearing tool for the area being cleared.
- TM 3-34.70 (23 Jul 2012), para 3-16
- 12K deep dive: How is a water-closet stoppage cleared?
- Use a force-cup plunger: pump it up and down until the water level drops, then place toilet paper in the bowl and flush to check that the stoppage is cleared. Or use a water-closet snake: push it into the bowl and turn the handle clockwise with a push-pull action until the water level drops, then check the same way.
- TM 3-34.70 (23 Jul 2012), para 3-17
- 12K deep dive: How is a lavatory or sink P-trap stoppage cleared with a plunger?
- Place a wet rag in the bowl's overflow opening and remove a pop-up plug if the lavatory has one. Set a plunger over the waste outlet and push it up and down until the water completely drains, then remove the rag, replace the plug if needed, and run water through the drain to confirm the stoppage is gone. A P-trap stoppage can also be removed by disassembling the trap, clearing it, reassembling it, and flushing with water.
- TM 3-34.70 (23 Jul 2012), para 3-18
- 12K deep dive: How is a stoppage beyond a lavatory or sink P-trap cleared?
- Place a container under the P-trap to catch water, then disassemble the P-trap. Push a snake into the drain line, turning it with a push-pull action until it moves freely. Remove the snake, replace the P-trap, and run water through the drain line to ensure free flow.
- TM 3-34.70 (23 Jul 2012), para 3-19
- 12K deep dive: How is a bathtub P-trap stoppage cleared?
- Try a vacuum plunger first. If that does not work, remove the stopper linkage and the overflow cover, push a 1/4- to 1/2-inch drain snake into the overflow opening until it meets resistance, and turn it with a push-pull motion until it turns freely. Remove the snake, run water to check that the stoppage is cleared, and replace the overflow cover and linkage.
- TM 3-34.70 (23 Jul 2012), para 3-21
- 12K deep dive: How can a shower drain stoppage be cleared with a hose?
- Remove the strainer, hook a water hose to a source of water and place the other end in the drain, stuff rags around the hose to form a tight seal, and turn the water on full force, then off and on again. The surge of water will clear the stoppage. Replace the strainer. A 1/4- to 1/2-inch snake can also be used after the strainer is removed.
- TM 3-34.70 (23 Jul 2012), para 3-23
- 12K deep dive: How are branch and main waste-line stoppages in a building cleared?
- Both are cleared through a cleanout plug. For a branch line, remove the closest cleanout plug, clear the stoppage with a snake, replace the plug, and run water through the drain to confirm it is clear. For a main line, use a 3/4- to 1-inch heavy-duty snake after removing the closest cleanout plug, then replace the plug.
- TM 3-34.70 (23 Jul 2012), paras 3-25 and 3-26
- 12K deep dive: What principle is used when clearing a grease-trap stoppage, and what are the steps?
- Grease is lighter than water and will rise to the top. Remove the top cover and dip out the grease with a ladle, scrape the walls and bottom after the grease is scooped out, and flush with clear water.
- TM 3-34.70 (23 Jul 2012), para 3-27
- 12K deep dive: What carbon monoxide and lead-poisoning hazards exist around water-heater burners, and how are they reduced?
- Carbon monoxide is a colorless, odorless gas given off when burning is incomplete; remove the hazard by proper operation and adequate ventilation. Lead poisoning results from using leaded fuel such as ethyl gasoline; breathing the vapors is very dangerous, and adequate ventilation is absolutely necessary.
- TM 3-34.70 (23 Jul 2012), para 5-16
- 12K deep dive: How can a water-heater burner cause an explosion?
- If the flame of a burner goes out and the fuel is not turned off or relighted immediately, gas may build up. An explosion can result if that gas is ignited. The vapor burner is more dangerous than the oil-water flash burner, but the vapor burner's automatic relighting device reduces the chance of an explosion.
- TM 3-34.70 (23 Jul 2012), para 5-16
- 12K deep dive: What maximum hourly hot-water use per person does TM 3-34.70 list for schools, offices, and barracks?
- Generally, the maximum hourly use of hot water per person is 2 or 3 gallons for schools, 4 or 5 gallons for offices, and 8 to 10 gallons for living quarters and barracks.
- TM 3-34.70 (23 Jul 2012), para 5-12
- 12K deep dive: What approximate working-load percentages does TM 3-34.70 list for water heaters?
- The working load is the percentage of maximum load expected under normal conditions in any given hour: about 25 percent for school or office buildings, 35 percent for residential buildings, and 40 percent for barracks buildings.
- TM 3-34.70 (23 Jul 2012), para 5-13
- 12K deep dive: How should fixture supply risers be connected to the main supply and supported?
- Use reducing Ts to connect fixture supply risers to the main supply, and run the risers through the interior walls. Tighten all joints before the partitions are finished. Use pipe rests or clamps to support vertical fixture supply risers at each floor level; they must not depend on the horizontal branches for support. Grade horizontal fixture branches upward toward the vertical risers.
- TM 3-34.70 (23 Jul 2012), para 1-25
- 12K deep dive: How should a hot-water supply be graded and valved?
- Grade the hot-water supply to a centrally located drip cock near the water heater. Water for fixtures at various levels is taken from the main hot-water supply by fixture supply risers, and each of the risers should have a valve.
- TM 3-34.70 (23 Jul 2012), para 1-46
- 12K deep dive: What supply-pipe diameters does TM 3-34.70 list for common plumbing fixtures?
- 1/2 inch for a lavatory, shower, bathtub, kitchen sink, slop sink, laundry tub, drinking fountain, and water-closet tank; 3/4 inch for a scullery sink and for a urinal with a diaphragm-type flushometer; and 1 inch for a water-closet flushometer.
- TM 3-34.70 (23 Jul 2012), para 4-1, table 4-1
- 12K deep dive: What is a water closet made of, and what four flushing-action types are available?
- Water closets are made of vitreous china and can be installed on a floor or hung from a wall. The flushing-action types are washdown bowl, washdown bowl with jet, reverse-trap bowl, and siphon-jet bowl. Each type has a built-in trap containing a water seal, based on the same atmospheric pressure on both sides of the trap.
- TM 3-34.70 (23 Jul 2012), paras 4-2 and 4-3
- 12K deep dive: How do the four water-closet bowl types differ?
- The common washdown bowl is the least expensive and simplest, with the trap at the front and small rim streams flushing the bowl. A washdown bowl with jet has a small hole in the bottom that delivers a direct jet into the upper arm of the trap to start siphoning. A reverse-trap bowl has the trap at the rear, holds more water, and is quieter. The siphon-jet bowl is the most efficient, quietest, and most expensive; it looks like the reverse-trap bowl but holds more water and is almost completely filled.
- TM 3-34.70 (23 Jul 2012), paras 4-4, 4-5, 4-6, and 4-7
- 12K deep dive: How are water-closet tanks classified, and what two tank flushing mechanisms are most common?
- Tanks are close-coupled (floor-mounted and attached to a floor-mounted bowl) or wall hung (attached to the wall above the bowl). The flushing mechanism is the same for both types. The two most common mechanisms are the ball cock and the float cup. After installation, connect the water supply, check operation, and adjust the mechanism to maintain the proper water level in the tank.
- TM 3-34.70 (23 Jul 2012), paras 4-11 and 4-15
- 12K deep dive: What does a flushometer valve do, and what are the most common types?
- A flushometer valve delivers, under pressure, a preset amount of water directly into a water closet for flushing. The flushing action is quick and shuts off automatically. The most common types are the diaphragm and the piston. After installation, turn on the water supply and operate the flushometer several times, checking for leaks and proper operation.
- TM 3-34.70 (23 Jul 2012), para 4-16
- 12K deep dive: What are the three types of urinals, and how is each flushed?
- Urinal types are wall hung, stall, and trough. A wall-hung urinal can have a built-in water-seal trap or a P-trap with washdown or siphon-jet action, and it is flushed by a flushometer valve. A stall urinal is set into the floor, with a beehive strainer over the waste outlet caulked to a P-trap below the floor, and it uses washdown action from a flushometer. A trough urinal is wall hung with a flush tank and a perforated pipe across the rear that lets water flow down the back of the trough when flushed.
- TM 3-34.70 (23 Jul 2012), paras 4-39, 4-40, 4-41, 4-42, and 4-43
- 12K deep dive: What is the most important requirement when installing a shower?
- Complete waterproofing. Tile installed with good-quality waterproof cement provides a waterproofed wall. For the floor, a waterproof base (shower pan) under the shower is necessary, because water standing on the tile surface can seep through and cause leaks.
- TM 3-34.70 (23 Jul 2012), para 4-50
- 12K deep dive: On an exposed shower supply, which side is cold water and which is hot?
- The cold-water line is brought in on the right side, and the hot-water line is brought in on the left. The lines are tied into a single water line ending in a showerhead.
- TM 3-34.70 (23 Jul 2012), para 4-54
- 12K deep dive: What temperature range can a gas water-heater thermostat keep, and what is an electric water heater’s advantage in location?
- A gas water heater’s thermostat is automatic and will keep water at any temperature from 110 to 165 degrees Fahrenheit, according to the setting. An electric water heater normally has two immersion-type heating elements, does not need a flue or smoke pipe because there are no burning products, and may be located away from the chimney, for example in a closet.
- TM 3-34.70 (23 Jul 2012), paras 5-5 and 5-7
- 12K deep dive: What is a lavatory used for, and what materials are lavatories made of?
- A lavatory is designed for washing one’s hands and face. Lavatories are made of vitreous china, enameled cast iron, stainless steel, and plastic. Hot and cold water is supplied through the supply system, and the waste drains into the sanitary sewer.
- TM 3-34.70 (23 Jul 2012), para 4-24
- 12K deep dive: What is a scullery sink, and where is it used?
- Scullery sinks are large, deep sinks used in mess-hall-type facilities. They need only installation of faucets and connection to waste and water-supply lines.
- TM 3-34.70 (23 Jul 2012), para 4-36
- 12K deep dive: What must be true of every pipe joint, and what is oakum used for?
- All joints must be watertight and gastight. Oakum is hemp or jute fibers soaked with a bituminous compound, loosely twisted or spun into a rope or yarn. It is used with lead or other materials to make caulked joints in hub-and-spigot cast-iron pipe and in vitrified-clay tile or concrete pipe.
- TM 3-34.70 (23 Jul 2012), paras 6-2 and 6-3
- 12K deep dive: What solder and flux does TM 3-34.70 specify for copper tubing, and what is solvent cement used for?
- A nonacid flux, such as rosin, must be used. A 95 percent tin and 5 percent aluminum compound or substance is used for copper tubing. Solvent cement is used with plastic fittings to join rigid plastic pipe; the cement comes in several types for each different plastic pipe and fitting.
- TM 3-34.70 (23 Jul 2012), paras 6-6 and 6-7
12K – Deep Dive: Pipes, Valves, Stacks, Traps, Vents, Gas Piping & Pumps
Source: TM 3-34.70 (Plumbing, Pipe Fitting and Sewerage, 23 Jul 2012). Complements mos-12k-plumber and mos-12k-3; does not repeat those cards. Verify current editions.
- 12K deep dive: What is a pipe engagement, and how is face-to-face pipe length determined?
- A pipe engagement is the distance the pipe goes into a fitting, determined by the pipe's nominal size diameter. A face-to-face measure is the distance between the faces of each fitting. To find the pipe length needed, add the pipe-engagement distance for each fitting to the face-to-face measurement.
- TM 3-34.70 (23 Jul 2012), paras 6-16 and 6-19
- 12K deep dive: How is a center-to-center pipe length determined when fittings are on each end?
- Subtract the sum of both fitting dimensions and then add the sum of both pipe engagements.
- TM 3-34.70 (23 Jul 2012), para 6-20
- 12K deep dive: When is service-weight versus extra-heavy cast-iron soil pipe used?
- Cast-iron soil pipe is used for sewers, drains, stacks, and vents in a waste system. Service weight (SW) is used in households and is adequate for most military construction. Extra-heavy weight (XH) is used where liquids may corrode the pipe or where greater strength is needed for tall stacks or under roadways.
- TM 3-34.70 (23 Jul 2012), para 6-24
- 12K deep dive: What is a closet bend?
- A closet bend is a special fitting that connects a soil-waste branch line for a water closet. It can be plain or tapped for waste or venting, and closet bends are made to fit different types of floor flanges.
- TM 3-34.70 (23 Jul 2012), para 6-34
- 12K deep dive: Why must cast-iron pipe be supported along runs and fittings?
- To prevent strain on the joints. The pipe must be supported both vertically and horizontally to maintain alignment and the proper drainage slope.
- TM 3-34.70 (23 Jul 2012), para 6-44
- 12K deep dive: What is galvanized-steel or iron pipe used for, and what strength is most common in plumbing?
- It can be used for hot- and cold-water supply distribution, certain drainage applications, and vent installations. It comes in standard, extra strong, and double extra strong (also described as Schedule 40 and Schedule 80). Schedule 40 standard is most commonly used in plumbing. Nominal diameters are 1/8 inch to 12 inches, and the pipe comes in 21-foot lengths, threaded or unthreaded.
- TM 3-34.70 (23 Jul 2012), paras 6-45 and 6-46
- 12K deep dive: What is a nipple, and how long is it?
- A nipple is used to make an extension from a fitting or to join two fittings. Nipples are pieces of pipe 12 inches or less in length, threaded on each end. There are close, shoulder, and long nipples.
- TM 3-34.70 (23 Jul 2012), para 6-53
- 12K deep dive: What lubricant is used when cutting threads on pipe, and when should threading be stopped?
- Cutting oil or lard oil is used as a lubricant. Pipe threads are cut at a taper and are identified as NPT. Too much thread is as undesirable as too little; a good rule is to cut threads until the pipe extends about 1/4 inch from the base of the dies.
- TM 3-34.70 (23 Jul 2012), paras 6-13, 6-57, and 6-59
- 12K deep dive: Where is pipe-joint compound or Teflon tape applied when joining threaded pipe?
- Apply pipe-joint compound or Teflon tape to the pipe threads only, not to the fitting threads. Check both the fitting and pipe threads for cleanliness and damage first, screw the fitting on hand tight, and then tighten it using two pipe wrenches, with a backup wrench on the fitting to keep it from turning if no vise is available.
- TM 3-34.70 (23 Jul 2012), para 6-60
- 12K deep dive: What are the types of copper tubing, and how do their walls differ?
- Type K is thick-walled, rigid or flexible, in 20-foot lengths or 100-foot coils, from 1/4 inch to 12 inches in diameter. Type L is medium-walled, rigid or flexible, in the same lengths and diameters. Type M is thin-walled, rigid only, in 20-foot lengths, with the same diameters. Drain-waste-vent (DWV) copper is available in 20-foot lengths from 1 1/4 to 8 inches in diameter. Copper tubing is lightweight, easily joined, and corrosion-resistant.
- TM 3-34.70 (23 Jul 2012), paras 6-61 and 6-63
- 12K deep dive: What safety precautions must be taken when soldering a copper joint?
- When the joint is close to wood or other combustible material, place an insulation sheet or sheet metal between the fitting and the combustible material before applying the torch flame. Keep the joint connection motionless while the solder is cooling so the joint will be leakproof. Heat the fitting with the torch, and when the flux is bubbling, apply 95-5 (95 percent tin and 5 percent aluminum) nonacid solder so it flows into and completely around the joint.
- TM 3-34.70 (23 Jul 2012), para 6-70 (including CAUTION)
- 12K deep dive: What is a flared joint used for, and what is swaging?
- A flared joint is used with flexible copper tubing; the flare on the end can be made with a flaring tool or a flanging tool. Swaging joins two sections of thin-walled copper tubing without a fitting: a swaging tool enlarges one tube end, the sections are connected, and the joint is soldered.
- TM 3-34.70 (23 Jul 2012), paras 6-71 and 6-73
- 12K deep dive: How do PVC, CPVC, and ABS plastic pipe differ in use?
- PVC is cream or white and is used only for cold-water pipelines, sanitary drainage, and venting, in 10- and 20-foot lengths from 1/2 inch to 6 inches. CPVC is light or cream and is used for hot-water pipelines (and may also be used for cold-water lines), in 10-foot lengths in 1/2-inch and 3/4-inch diameters. ABS is black or gray and is used for above- and below-ground sanitary drainage and venting, in 10- and 20-foot lengths from 1 1/4 to 6 inches.
- TM 3-34.70 (23 Jul 2012), paras 6-79, 6-80, and 6-81
- 12K deep dive: How is a rigid plastic-pipe solvent-cement joint made, and how long should it be held?
- Inspect the pipe end for burrs and the fitting for cracks, then clean the pipe and the inside of the fitting with an authorized cleaning primer. Coat the outside of the pipe end and the inside of the fitting with the appropriate solvent cement, push the pipe in as quickly and as far as it will go, and give the fitting a quarter turn to spread the cement. Hold the joint for about 30 seconds to be sure it is solidly set, then wipe off excess cement. The cement melts the plastic of the pipe and fitting to weld them together and sets fast.
- TM 3-34.70 (23 Jul 2012), para 6-91
- 12K deep dive: How should plastic pipe be supported compared with metal pipe?
- Plastic pipe is not as stiff as metal pipe, so both horizontal and vertical runs should be supported more often. Support joint connections in the same manner as metal pipe.
- TM 3-34.70 (23 Jul 2012), para 6-93
- 12K deep dive: What is bituminous-fiber (“orange burg”) pipe used for?
- Bituminous-fiber pipe, often called orange burg, is used underground for house-to-sewer and house-to-septic-tank waste lines and for storm-drainage lines to dry wells. Perforated pipe is used for septic-tank disposal fields and for footing drains and other subsurface drainage. It is lightweight, easily joined, and corrosion-resistant.
- TM 3-34.70 (23 Jul 2012), para 6-94
- 12K deep dive: What is vitrified-clay pipe used for, and what safety rule applies when cutting it?
- Vitrified-clay pipe, also called terra-cotta, is used underground for sanitary and storm drainage pipelines outside of buildings. When it must be cut, use a brick chisel and hammer, scoring lightly around the circumference and deepening the cut gradually until the pipe breaks cleanly. Clay pipe is brittle, so cut it with care. Wear safety glasses when cutting clay pipe to avoid eye injury.
- TM 3-34.70 (23 Jul 2012), paras 6-106 and 6-110 (including WARNING)
- 12K deep dive: What is cast-iron pressure pipe used for, and is it still common?
- Cast-iron pressure pipe, also called corporation, is used for water-supply mains. It may be hub-and-spigot pattern or have flanged ends for bolting connections. The TM notes that cast-iron pressure pipe is seldom used today.
- TM 3-34.70 (23 Jul 2012), para 6-115
- 12K deep dive: What is a gate valve used for, and what are its three models?
- A gate valve is used to start or stop liquid, steam, or gas flow. It has a split or solid wedge disk that fits into a machined surface called a seat. Raising the disk starts the flow and seating the disk stops it. Gate valves come in three models: rising stem outside screw and yoke, rising stem inside the screw, and nonrising stem inside screw.
- TM 3-34.70 (23 Jul 2012), para 7-2
- 12K deep dive: How does a globe valve work, and what is an angle valve?
- A globe valve is a compression-type valve that controls liquid flow with a circular disk forced onto or withdrawn from an annular ring seat around the opening. All globe valves operate with a rising stem. An angle valve is a globe valve with the inlet and outlet at a 90-degree angle to one another. Angle valves are recommended for frequent operation, throttling, and/or a positive shutoff when closed.
- TM 3-34.70 (23 Jul 2012), paras 7-3 and 7-4
- 12K deep dive: How do swing and lift check valves differ, and when is each used?
- A check valve permits flow in one direction only and closes automatically to prevent backflow. Swing check valves are used in pipelines where pressure and velocity of flow are low. Lift check valves are used where pressure and velocity of flow are high.
- TM 3-34.70 (23 Jul 2012), para 7-5
- 12K deep dive: What is a stop-and-waste valve, and may gas and water valves be interchanged?
- A stop-and-waste valve, also known as a bleeder valve, has a plug on the outlet side that allows water to be drained from pipelines. Gas and water valves are not interchangeable. Other valves include reducing valves to reduce water pressure going into a building, and pressure- or temperature-relief valves for water heaters.
- TM 3-34.70 (23 Jul 2012), paras 7-6 and 7-7
- 12K deep dive: What usually causes valve leaks, and what should be done before any faucet repair?
- Check all valves regularly for leaks. Most leaks are from leaky washers or bonnets that have been used for a long period of time. Before repairing any faucet, drain it by turning the water off at the fixture shutoff valve. When repairing a compression (washer) faucet, always check the valve seat; if it is chipped or rough, reface it with a refacing tool or replace it.
- TM 3-34.70 (23 Jul 2012), paras 7-8, 7-20, and 7-21
- 12K deep dive: How does a compression faucet differ from a noncompression faucet?
- A compression (or washer) faucet works by raising the washer on a seat for water flow and compressing the washer onto the seat to stop the flow; it can be a single faucet for hot or cold water or a combination faucet. A noncompression faucet, commonly called washerless, has a single lever or knob that opens and closes ports for water flow and shutoff. Noncompression faucets come in three basic types: valve, ball, and cartridge, controlled by a single handle.
- TM 3-34.70 (23 Jul 2012), paras 7-16 and 7-17
- 12K deep dive: What materials are usually used for soil stacks and for fixture branches?
- Stacks and branches may be made of cast iron, threaded iron, copper, or plastic pipe. Soil stacks are usually hubless cast iron with neoprene sleeve gaskets or plastic pipe; copper is also used because it is easily installed. Branches are usually threaded galvanized-steel pipe with recessed drainage fittings, copper pipe (DWV), or plastic pipe (ABS).
- TM 3-34.70 (23 Jul 2012), para 8-1
- 12K deep dive: In the TM 3-34.70 example, what stack size is required for 45 drainage fixture units?
- A 3-inch stack for cast-iron, steel, or plastic pipe, and a 2-inch stack for copper pipe. Table 8-1 lists maximum fixture units per stack, including 60 for a 3-inch pipe and 500 for a 4-inch pipe.
- TM 3-34.70 (23 Jul 2012), para 8-2, table 8-1
- 12K deep dive: How is a water closet usually connected to the stack, and what size is the closet bend?
- A water closet has no individual waste pipe. It is usually connected directly into the stack with a short branch attached to a closet bend. The closet bend is 3 or 4 inches in diameter if it is cast iron, steel, or plastic, and 3 inches if it is copper.
- TM 3-34.70 (23 Jul 2012), para 8-3
- 12K deep dive: What minimum waste-pipe sizes does TM 3-34.70 list for a lavatory, urinal, single shower, kitchen sink, and drinking fountain?
- Lavatory waste is a minimum of 1 1/4 inches (1 1/2 inches is more satisfactory if the pipe is not copper). A urinal should have an effective strainer, with waste pipe 2 inches for cast iron, steel, or plastic and 1 1/2 inches for copper. A single shower uses 2 inches for cast iron, steel, or plastic and 1 1/2 inches for copper; a shower room needs 3 or 4 inches. A kitchen sink needs a 1 1/2-inch waste pipe that is short and as free from offset as possible. A drinking fountain, which carries clear water waste, needs 1 1/4 inches.
- TM 3-34.70 (23 Jul 2012), paras 8-4, 8-5, 8-6, 8-7, and 8-10
- 12K deep dive: What waste-pipe sizes do slop sinks and scullery sinks require?
- A trap-to-floor (stand-trap) slop sink requires a 3-inch waste pipe, and a trap-to-wall slop sink requires a 2-inch waste pipe; in both types, copper pipe may be a size smaller. A scullery sink should use a 2-inch waste pipe because a large amount of grease is passed into the pipe through a grease trap.
- TM 3-34.70 (23 Jul 2012), paras 8-8 and 8-9
- 12K deep dive: How is the stack connected at the house drain, and how far must the vent through the roof (VTR) extend?
- Connect the stack to the house drain with a long-sweep 1/4 bend to keep pressure to a minimum, then connect a test T so its side opening is 12 inches above the finished floor. After the main vent T is installed, run the main soil-and-waste vent through the roof to form the VTR. The VTR pipe must be as large as or larger than the stack and must extend a minimum of 12 inches above the roof. Use roof flashing to make the opening watertight. In below-freezing areas, use a pipe a size or two larger than the stack, or use insulation, high flashing, or a frost-proof cover, so frost does not close the vent.
- TM 3-34.70 (23 Jul 2012), para 8-12
- 12K deep dive: How high should the main vent T be placed in the stack?
- The main vent T should be placed in the stack at least 6 inches above the flood level of the highest fixture in the installation. It joins the main vent to the main soil-and-waste vent.
- TM 3-34.70 (23 Jul 2012), para 8-13
- 12K deep dive: What slope should horizontal waste branches have, and where must cleanouts be installed?
- Branches should slope 1/4 inch per foot from the fixture to the stack. Install a cleanout for every change of direction and for each horizontal line 2 feet long or longer. Cleanouts should be the same diameter as the waste line. No branch may be larger than the soil (waste) stack.
- TM 3-34.70 (23 Jul 2012), paras 8-14, 8-15, and 8-16
- 12K deep dive: How should stacks and branches be supported?
- Support them so the weight of the pipe will not bear on the joints, which are the weakest points in the line. Cast-iron soil-pipe stacks and branches should be supported at all joints. The bend at the base of the stack should rest on a concrete or masonry support. Support threaded galvanized-iron or steel waste pipe, plastic pipe, and copper-tubing drain and vent lines at each floor level. Support horizontal cast-iron runs with sturdy iron-ring hangers as close to the caulked joint as possible.
- TM 3-34.70 (23 Jul 2012), para 8-17
- 12K deep dive: How is a water test of a waste system performed, and what result is satisfactory?
- Seal the branches and vent lines and place a test plug in the test T. Fill the system with water and check for a drop in the water level. The test is satisfactory if the water level does not fall more than 4 inches in a 30-minute period. If the level drops noticeably, check each joint for leaks, make leaking joints watertight, and replace any defective material.
- TM 3-34.70 (23 Jul 2012), para 8-20
- 12K deep dive: How is an air test of a waste system performed, and what result is satisfactory?
- Apply an air pressure of about 5 psi, measured by a gauge. In a satisfactory test, the line should hold 5 psi for 15 minutes. A drop in the mercury column shows a leaky joint. Listen for escaping air to help locate leaks; if no sound is heard and pressure is falling, apply a soap solution to the joints, and bubbles will form at a leak.
- TM 3-34.70 (23 Jul 2012), para 8-21
- 12K deep dive: What 12-hour test is done on some waste piping before a water or air test?
- Seal all branches and vent lines and place a ratchet test plug in the test T at the base of the stack. Fill the system with water from the top of the main soil-and-waste vent, and keep it filled for at least 12 hours to allow the oakum in the joints to swell and form a watertight seal. After that 12-hour test, perform either a water test or an air test.
- TM 3-34.70 (23 Jul 2012), paras 8-22 and 8-23
- 12K deep dive: What types of water-seal traps does TM 3-34.70 list, and which ones are not used in modern plumbing?
- The types are a P-trap, an S-trap, a 3/4 S-trap, and a drum trap. The P-trap is the most widely used for fixtures; it can be plastic or chromed tubular brass, most commonly 1 1/4 and 1 1/2 inches in diameter, and most have a cleanout plug. A drum trap is used mostly for bathtubs (and can be used in kitchen sinks); it is 3 or 4 inches in diameter and holds and discharges a greater volume of water than a P-trap. The full S-trap and 3/4 S-trap are not used in modern plumbing; if one is in place, remove it and replace it with a P-trap.
- TM 3-34.70 (23 Jul 2012), paras 9-3, 9-4, 9-5, and 9-6
- 12K deep dive: How deep is a common trap seal, and what usually causes trap-seal loss?
- The most common trap seal has a depth of 2 inches between the weir and the top dip. A deep-seal trap has a depth of 4 inches. If the water seal is lost, dangerous sewer gases can enter the building through the fixture. Trap-seal loss usually results from inadequate venting of the trap. Venting lets the atmosphere enter the discharge side of a trap so the pressures tend to equalize and the seal is not lost by siphonage. At sea level, atmospheric pressure is about 14.7 psi.
- TM 3-34.70 (23 Jul 2012), paras 9-7 and 9-8
- 12K deep dive: What is direct (self-) siphonage, and which fixtures rarely lose their trap seal that way?
- Direct siphonage occurs in unvented traps that serve oval-bottom fixtures such as lavatories. Those fixtures discharge rapidly and do not have the final small trickle of water needed to reseal the trap, so the waste pipe fills, pressure on the discharge side drops, and the seal is forced out. In a flat-bottom lavatory, the last few ounces of water come in a slow trickle and reseal the trap. Showers, laundry tubs, sinks, and bathtubs rarely lose trap seal by direct siphonage.
- TM 3-34.70 (23 Jul 2012), paras 9-9 and 9-10
- 12K deep dive: What is indirect siphonage of a trap?
- Indirect siphonage is caused by a large discharge of water from a fixture one or more floors above the affected fixture. That discharge tends to form a slug in the stack; as the slug passes the takeoff of the fixture below, air is pulled out of the lower fixture’s waste line, reducing pressure on the discharge side of the trap. There is no reseal until the lower fixture discharges.
- TM 3-34.70 (23 Jul 2012), para 9-12
- 12K deep dive: How can back pressure or capillary action cause trap-seal loss?
- Back pressure is caused by simultaneous fixture use that overtaxes the system. A large flow may completely fill the pipe so compressed gases cannot exhaust at a roof terminal; as the water falls, pressure increases and the trap seal blows out of the fixture. Capillary action occurs when a foreign object lodged in the trap acts as a wick and carries water over the outlet side until the seal is ineffective. Rags, string, lint, and hair commonly cause this problem.
- TM 3-34.70 (23 Jul 2012), paras 9-13 and 9-14
- 12K deep dive: When does a trap lose its seal by evaporation, and what is the best solution?
- Evaporation only occurs when a fixture is not used for a long time. A trap in a warm, dry place loses water seal more rapidly than one in a cool, damp place, and ventilation does not solve the problem. The best solution is a deep-seal trap, though one disadvantage is that solid wastes collect in the bottom of the trap and clog the pipe.
- TM 3-34.70 (23 Jul 2012), para 9-15
- 12K deep dive: What is the main vent, and how should it be connected in a building of three or more stories?
- The main vent is a vertical pipe connecting fixture vents to the main soil-and-waste vent or directly to the atmosphere. In a building of three or more stories, the main vent should be connected to the bottom of the soil stack to prevent pressure on the lower branches. Usually it is within several feet of, and parallel to, the main soil-and-waste stack, but it may be offset where there are space problems.
- TM 3-34.70 (23 Jul 2012), paras 9-16 and 9-17
- 12K deep dive: What is an individual (back or continuous) vent, and what are the maximum distances from fixture trap to vent?
- The individual vent, also called a back vent or continuous vent, is the most common and can be adapted to all fixtures. It prevents both direct and indirect siphonage. Assuming a drop of 1/4 inch per foot, the maximum distances from the fixture trap to the vent are 2 feet 6 inches for a 1 1/4-inch fixture drain, 3 feet 6 inches for 1 1/2 inches, 5 feet for 2 inches, 6 feet for 3 inches, and 10 feet for 4 inches.
- TM 3-34.70 (23 Jul 2012), para 9-18, table 9-1
- 12K deep dive: What is a common vent, and what is a circuit vent?
- Fixtures mounted side by side or back to back are common-vented; both fixtures discharge into a double sanitary T with deflectors, usually where two bathrooms have a common partition. A circuit vent extends from the main vent to connections on the horizontal soil or waste branch between the fixture connections and is used for a battery of two or more fixtures, such as lavatories. A maximum of eight fixtures are permitted on any one circuit vent. Connect the vent into the top of the branch rather than its side to reduce clogging.
- TM 3-34.70 (23 Jul 2012), paras 9-20 and 9-21
- 12K deep dive: What is a wet vent, and what is its disadvantage?
- A wet vent is part of a vent line through which liquid wastes flow from another fixture that has an individual vent. It is used most commonly on a small group of bathroom fixtures. A disadvantage is that the vent tends to become fouled with waste material, which reduces its diameter or causes a stoppage. The wet-vent pipe must be large enough for the fixtures based on the total drainage fixture units.
- TM 3-34.70 (23 Jul 2012), para 9-22
- 12K deep dive: What minimum vent-pipe sizes does TM 3-34.70 require?
- Never use a pipe smaller than 2 inches in diameter for ventilation. The main vent must be at least one-half the size of the stack, and the main soil-and-waste vent must be at least as large as the stack.
- TM 3-34.70 (23 Jul 2012), paras 9-23 and 9-24
- 12K deep dive: What is the minimum size of a steam supply main, and how should steam pipes be pitched?
- Do not use a supply main that is less than 2 inches in diameter, and the diameter of the far end should be no less than one-half the diameter at the largest part. Slope all pipes to allow condensation to drain toward the boiler. The pitch of the main should not be less than 1/4 inch per 10 feet. The pitch of horizontal runouts to risers and radiators should not be less than 1/2 inch per foot; where that pitch is not possible, runouts over 8 feet long should be one size larger than otherwise needed.
- TM 3-34.70 (23 Jul 2012), paras 10-2, 10-4, and 10-5
- 12K deep dive: What safety steps must a plumber take before working on steam lines?
- Shut off all the steam lines and remove the pressure, and allow the lines to cool before working on them. Insulate all steam lines passing within 6 inches of combustible materials, and insulate exposed steam lines that are within easy reach of personnel. Equip all steam boilers with proper pressure- and temperature-relief valves. Because of the high pressures and temperatures, death or physical injury can result from failure to use caution and to follow procedures.
- TM 3-34.70 (23 Jul 2012), para 10-8 (including DANGER)
- 12K deep dive: Which valve is most satisfactory for steam piping, and which globe-valve washer should not be used?
- The gate valve is the most satisfactory valve for steam piping; when open it allows ready passage of steam, and when closed it forms a leakproof shutoff. Globe valves should not be used with fiber disk washers, because those washers wear rapidly under high pressure and temperature.
- TM 3-34.70 (23 Jul 2012), para 10-6
- 12K deep dive: Why can water hammer occur in a steam system?
- Faulty piping installation causes most snapping, cracking, and rattling noises in steam-distribution or return systems. Live steam in contact with water or moisture in the pockets causes water hammer. This may occur in the distribution system because of high water levels in the boilers, and it occurs more often in return-condensation steam lines when steam is leaking or blowing directly through traps into those lines.
- TM 3-34.70 (23 Jul 2012), para 10-5
- 12K deep dive: What are the hazards of natural and manufactured fuel gas?
- In its natural state, fuel gas is colorless and odorless, with a specific gravity of about one-half that of ordinary air. Chemicals are added so that users can detect a leak by its odor. Natural gas (methane) is not poisonous but can cause suffocation in a closed space. Manufactured gas can be poisonous, since it may contain carbon monoxide. It is explosive under certain conditions.
- TM 3-34.70 (23 Jul 2012), para 10-9
- 12K deep dive: What pipe may be used for gas service, and what must not be used?
- Piping used for water services is suitable for gas piping. Iron or steel pipe with threaded joints is usually used, because fuel gas does not corrode these metals. Use galvanized pipe from the meter main to the building; the branches can be copper. Do not use lead pipe or rubber tubing to carry gas.
- TM 3-34.70 (23 Jul 2012), para 10-10
- 12K deep dive: How must plastic gas pipe be joined, and when must it not be installed?
- When plastic pipe is used for gas services, heat-weld the joints; do not use glue or cement. Do not install plastic pipe above ground in distribution systems with pressure greater than 50 psi of grade, or where the operating temperatures will be below -20 degrees Fahrenheit or above 100 degrees Fahrenheit.
- TM 3-34.70 (23 Jul 2012), para 10-11
- 12K deep dive: How should gas piping be sloped, dripped, and branched?
- Because fuel gas contains moisture, all gas pipes should slope. Install capped drip legs to allow drainage of moisture that might condense in the pipe, check and empty the drips when necessary, and do not install drips where moisture may freeze. Avoid traps in the pipes. Take all branches off the top of the service pipe to prevent water from collecting in the branches. Gas piping should be exposed, and unions and bells should be visible to allow frequent inspections.
- TM 3-34.70 (23 Jul 2012), para 10-12
- 12K deep dive: How must a newly installed gas main and service line be tested?
- After installation, air-test the entire gas main and service-line system under a pressure that is at least 50 percent of the operating pressure. Test pressure must be at least 75 psi.
- TM 3-34.70 (23 Jul 2012), para 10-13
- 12K deep dive: How does a compressed-air tank’s safety valve prevent an explosion?
- Air is stored in a tank until needed. When the amount of air in the tank reaches the desired pressure, the compressor shuts off automatically. If the pressure-control valve fails, the safety valve reduces the pressure on the tank, which prevents an explosion. Compressed air is drawn from the tank through a reducing valve that may be set to furnish any desired pressure to the equipment.
- TM 3-34.70 (23 Jul 2012), para 10-15
- 12K deep dive: Why are dresser couplings used for underground gas and air piping?
- Many gas and air pipes are laid underground. Threading of pipe reduces the wall thickness by about 40 percent, and the pipe is more likely to corrode or be damaged by vibration. For that reason, dresser couplings are used for underground piping instead of threaded joints. They provide leakproof joints without reducing the pipe wall thickness.
- TM 3-34.70 (23 Jul 2012), para 10-17
- 12K deep dive: What safety rules apply when installing or repairing gas and air piping?
- Never smoke in an area where gas piping is being installed or repaired; it is not permitted. Never use matches to test for gas leaks. Locate the meter and the riser pipes some distance from electric meters, switches, fuses, and other equipment. Install adequate pressure-relief valves on air compressors. Test all lines before use. Remove the pressure from all the lines before working on them. Provide protection for the pipes against freezing of condensed water in unheated locations.
- TM 3-34.70 (23 Jul 2012), para 10-18
- 12K deep dive: How does a centrifugal pump work, and what capacity range does TM 3-34.70 list?
- When a liquid whirls around a point, a centrifugal force is created, forcing the fluid outward from the center. Larger centrifugal pumps can develop a pressure great enough to raise a column of liquid more than 100 feet. Their capacity ranges from 5,000 to 200,000 gallons per hour.
- TM 3-34.70 (23 Jul 2012), para 11-1
- 12K deep dive: How does a submerged pump differ from a submersible pump, and when should a submersible pump be used?
- In a submerged pump, the motor is placed above the water level and the pump itself is in the water; the motor is usually mounted near the wellhead and connected to the pump by a shaft. It is used mainly for shallow wells because long pump shafts vibrate. A submersible pump is connected directly to an electric motor in a single casing and is lowered into the well with the motor above the pump; both motor and pump may be below the water level. Use a submersible pump when the suction lift exceeds 25 feet.
- TM 3-34.70 (23 Jul 2012), paras 11-5, 11-6, and 11-7
- 12K deep dive: What is the maximum suction lift for a pump at sea level?
- If a perfect vacuum could be produced, atmospheric pressure would lift water to a maximum of 34 feet. Because a perfect vacuum is impossible, the suction lift from the source of water to the pump must never be more than 22 to 25 feet at sea level, and less at higher altitudes.
- TM 3-34.70 (23 Jul 2012), para 11-9
- 12K deep dive: What installation points does TM 3-34.70 emphasize for a centrifugal pump?
- Set the pump on a firm foundation to avoid vibration, and locate it as close to the water supply as possible. Make sure the suction hose has no collapsed lining, breaks, cuts, or pinholes, and tighten connections to prevent air leaks. Support the piping so the pump does not carry its weight. Make piping, especially on the suction side, as short as possible with few elbows. Place the suction pipe so it rises gradually toward the pump (not necessary on a self-priming centrifugal pump). Install a strainer on the suction line; the net on the strainer should be at least four times the size of the net on the suction pipe.
- TM 3-34.70 (23 Jul 2012), para 11-8
- 12K deep dive: What do the check, gate, and relief valves on a centrifugal pump do?
- A check valve on the suction side prevents the loss of priming liquid in the pump casing during idle periods; it allows liquid to flow in one direction only and usually opens or closes automatically. A foot valve on the end of the suction pipe is not required but may be provided to fill the pipe. A gate valve is hand-operated and used on discharge and suction lines to cut off flow; it should never be used to throttle or control flow, because the flow of liquid corrodes the gate. A relief valve is a safety valve designed to open when the liquid pressure in the pump becomes too high.
- TM 3-34.70 (23 Jul 2012), para 11-10
- 12K deep dive: How is a centrifugal pump primed?
- After installation, prime the pump by filling it with water. After the first priming, a self-priming centrifugal pump does not need to be reprimed unless it has been drained. To prime it, remove the priming plug on top of the pump casing, fill the case to the top with water, ensure that the valve on the discharge line is wide open, replace the plug, and start the pump.
- TM 3-34.70 (23 Jul 2012), para 11-11
- 12K deep dive: What are unions used for, and how do ground and flange unions seal?
- Unions are used to join the ends of two pipes that can be turned or disconnected. In a ground union, the pipes are screwed to the thread and shoulder pieces and drawn together by a collar, making a gastight and watertight joint. In a flange union, nuts and bolts pull the flanges together, and a gasket between the flanges makes a gastight and watertight joint.
- TM 3-34.70 (23 Jul 2012), para 6-52
- 12K deep dive: After cutting steel pipe, how are burrs removed, and how should the pipe be held in the vise?
- Lock the pipe tightly in the vise with the cutting mark about 8 inches from the vise. After the cut, push a reamer into the pipe and turn it clockwise in short, even strokes, keeping steady pressure against the pipe until the inside burrs are removed. If a three-wheel cutter is used, remove the outside burrs with a file.
- TM 3-34.70 (23 Jul 2012), para 6-57
- 12K deep dive: What temperature change can cause steam pipe to expand, and how is that stress absorbed?
- When steam passes through a pipe, the pipe becomes the same temperature as the steam and expands. For a temperature change of 900 degrees Fahrenheit, steel pipe would expand about 8 1/2 inches per 100 feet of length. To prevent undue stress on the pipe and transfer of that stress to appliances, insert a flexible connection that will expand and contract with the pipe, and install bends and loops in the pipe to absorb the forces of expansion and contraction.
- TM 3-34.70 (23 Jul 2012), para 10-3
- 12K deep dive: A running trap is used in a building drain line under what condition?
- A running trap is used in a building's drain line when the local plumbing code requires that the building drain be trapped. Traps are used on some fixtures and floor drains inside buildings.
- TM 3-34.70 (23 Jul 2012), para 9-2
- 12K deep dive: When is a sanitary T used, and when is a straight T used?
- Sanitary Ts are designed to carry drainage, and straight Ts are used for vent lines. Use a tapped T, either sanitary or straight, to connect threaded-pipe branch drains or vent lines. Use a test T for testing a newly installed waste system for leaks. A T’s size is always given first by the through section (run) and then by the takeoff (outlet).
- TM 3-34.70 (23 Jul 2012), para 6-31
- 12K deep dive: What are Y-branches used for, and what are the most common types?
- Y-branches are used to join one or more sanitary sewer branches or to connect a branch to a main line. This design allows a smoother change in flow direction. The most common types are 45-degree and 90-degree. A 90-degree Y-branch is also called a combination Y and 1/8 bend or T-Y; the double 90-degree Y-branch is used extensively in a unit-vent installation.
- TM 3-34.70 (23 Jul 2012), para 6-32
- 12K deep dive: How are cast-iron bends designated, and what fraction equals a 90-degree bend?
- The degree of direction change is given as a common math fraction. Bends are designated 1/16, 1/8, 1/6, 1/5, 1/4, and 1/2 as they change direction 22 1/2, 45, 60, 72, 90, and 180 degrees, respectively. These bends can be regular, short sweep, or long sweep.
- TM 3-34.70 (23 Jul 2012), para 6-33
- 12K deep dive: What are an offset, an increaser, a tucker coupling, and a sewer thimble used for?
- An offset carries a soil or waste line past an obstruction in a building; a 1/8-degree-bend offset gives a smoother transition than a regular offset. An increaser increases the diameter of a straight-through pipeline and is usually used at the top of a stack. A tucker-coupling fitting connects a hub-and-spigot pipe section to a threaded pipe section (a hub on one end and female threads on the other). A sewer thimble is a special fitting that connects the building sewer line to the main sewer line. A cleanout is a removable, threaded plug placed in drainage lines for cleaning or removing stoppages.
- TM 3-34.70 (23 Jul 2012), para 6-36
- 12K deep dive: What are plugs and caps used for during rough-in?
- Plugs and caps are used to seal off openings in other fittings or pipe ends. These fittings seal off a water system for testing. This rough-in system is in place until the fixtures are installed.
- TM 3-34.70 (23 Jul 2012), para 6-54
- 12K deep dive: How is a faucet installed on a lavatory or sink?
- Apply plumber’s putty on the bottom of the faucet (single or combination). If a gasket comes with the combination faucet, putty is not required. Place the faucet on the top rear of the bowl with the threaded ends through the holes, place a washer and attach a locknut to each threaded end under the bowl, tighten each locknut with a basin wrench, and wipe off any excess putty around the faucet.
- TM 3-34.70 (23 Jul 2012), para 7-19
- 12K deep dive: The stack is described as what kind of pipe run?
- The stack is one continuous pipe run that goes from the house drain up through the roof. Certain sections of the run are named for their function.
- TM 3-34.70 (23 Jul 2012), para 8-11
- 12K deep dive: What is steam used for, and what pipe is most steam piping made of?
- Steam is used mainly for space heating, cooking, and laundering. It is produced in a boiler and passes through steam headers and branch takeoffs to the steam appliances. Most steam pipes are wrought-iron or steel with threaded joints. Large, high-pressure, high-temperature systems use bolted-flange joints.
- TM 3-34.70 (23 Jul 2012), para 10-1
- 12K deep dive: Where is frost-proof insulation used on plumbing?
- Frost-proof insulation is used on cold-water service lines that pass through unheated areas and those that are located outside. A common supply is 3 feet long and 1 1/2 inches thick, with a canvas cover.
- TM 3-34.70 (23 Jul 2012), para 12-2
- 12K deep dive: What is antisweat insulation used for?
- Antisweat insulation is used on cold-water lines. It keeps water in the pipes colder and, if properly installed, prevents the pipes from sweating. The outer layer has a nap about 3 inches long, which extends beyond the joint to help make a perfect seal, and a canvas jacket is placed around each 3-foot length to protect the outer felt covering.
- TM 3-34.70 (23 Jul 2012), para 12-4
- 12K deep dive: What materials are used for flashing around stacks and for shower pans?
- Sheet metal, aluminum, lead, copper, and galvanized iron are used for flashing around stacks and for shower pans.
- TM 3-34.70 (23 Jul 2012), paras 6-10 and 6-11
12K – Thin Section: Electrical & Electronics (Electrically Cooled Fountain)
Source: TM 3-34.70/MCRP 3-17.7E (Plumbing, Pipe Fitting, and Sewerage, 23 Jul 2012). Complements mos-12k-plumber, mos-12k-3, and mos-12k-4; does not remake the underground-cable clearance, galvanic/electrolysis, dielectric-union, or electric water-heater cards. Verify current editions.
- 12K deep dive: What electrical requirement applies when installing an electrically cooled drinking fountain?
- The three types of drinking fountains are the pedestal, wall-hung, and electrically cooled. The electrically cooled fountain requires a nearby electrical outlet. Follow the manufacturer's instructions when installing a fountain.
- TM 3-34.70 (23 Jul 2012), paras 4-61 and 4-63
12K – Plumber
Source: DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K); DA Pam 611-21 ch. 10 MOS/skill-level classification listing (chapter-10-base); TM 3-34.70 (23 Jul 2012); ATP 3-34.40 (14 Apr 2023). Verify current editions.
- 12K: What is the primary role of the Army Plumber?
- Status: current MOS (DA Pam 611-21 ch. 10C). To install, repair, and maintain plumbing, water distribution, and sewage systems in construction projects and base camps.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) paras a and a(1)
- 12K: Where is 12K AIT?
- Fort Leonard Wood, MO – verify current length on goarmy.com.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) para b(6) (course under the USA Engineer School; ACASP alternative in b(7)); 10C gives the USAES address as Ft Leonard Wood, MO (DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12D) para a; DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12P) para b(9)). Course length not in 10C
- 12K: What does a 12K work on?
- Water supply lines, drain-waste-vent systems, fixtures, water heaters, pumps, and field sanitation systems.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) para a(1) (water systems, waste systems, water heaters, shower systems, fixtures); TM 3-34.70 (23 Jul 2012) ch. 1 (field water supply, wastewater and sanitation) and ch. 9 (traps and vents)
- 12K: What is the purpose of a P-trap?
- It holds water to block sewer gases from entering a building.
- TM 3-34.70 (23 Jul 2012) ch. 9 introduction and paras 9-1 to 9-3 (P-trap is the most common water-seal trap), 6-35 ("A trap provides a water seal, which keeps sewer gases from entering a building")
- 12K: What is a vent stack for?
- It allows sewer gases to escape and equalizes pressure so traps don't siphon.
- TM 3-34.70 (23 Jul 2012) ch. 9 introduction ("A vent is a pipe or opening that brings outside air into the plumbing system and equalizes the pressure on both sides of a trap to prevent trap seal loss") and figures 9-3/9-4 (direct and indirect siphonage)
- 12K: What is backflow, and how is it prevented?
- Water flowing in a pipe in the reverse of the intended direction (for example, contaminated water back into the potable supply). It is prevented with check valves, which close automatically to prevent backflow, and with anti-siphon features such as the siphon hole in a water heater's cold-water filler, which prevents back siphonage.
- TM 3-34.70 (23 Jul 2012) glossary ("backflow: water flowing in a pipe in the reverse of the intended direction"), para 7-5 (check valve operates "automatically to prevent backflow") and para 1-48 (siphon hole prevents back siphonage). "Air gap" was not found in TM 3-34.70
- 12K: What pipe materials are common?
- PVC, copper, PEX, and steel/cast iron depending on application.
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) para a(1) (steel, plastic, copper, cast iron and PEX pipes); TM 3-34.70 (23 Jul 2012) ch. 6 sections (galvanized-steel/iron pipe, copper tubing, plastic pipe; figure 6-6 cast-iron pipes)
- 12K: What safety concerns exist for plumbers?
- Molten lead (wear protective clothing, protective gloves, a respirator and goggles), overheating soldered joints, and wastewater that can contain pathogenic organisms and toxic chemicals.
- TM 3-34.70 (23 Jul 2012) para 6-41 WARNING (molten lead PPE), para 3-9 CAUTION (do not overheat solder joints) and para 1-93 (wastewater may contain "biological and pathogenic organisms, and toxic chemicals"). Trench and confined-space hazards were not found in TM 3-34.70 and were removed
- 12K: What is the skill progression for 12K?
- 12K has only two skill levels: 12K1O plumber (E3/E4) and 12K2O (SGT). At skill level 3, plumbers move to 12H Construction Engineering Supervisor (SSG, then SFC).
- DA Pam 611-21 ch. 10 MOS/skill-level classification listing (chapter-10-base) (12K1-2 only: E3/4, E5; 12H3 E6, 12H4 E7); DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12H) para a(1) (12H3O performs the duties of previous skill levels in MOS 12W, 12K or 12R)
- 12K: How does DA Pam 611-21 summarize the 12K major duties?
- The plumber installs and repairs pipe systems and fixtures, and petroleum pipeline systems. (ch. 10C)
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) para a
- 12K: What minimum ASVAB line score does DA Pam 611-21 list for 12K?
- 88 in GM (General Maintenance) (ch. 10C; verify current standards).
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) para b(4)(a) (GM 88; checked against 10C)
- 12K: What physical demands rating applies to 12K?
- Moderate (Gold), with a minimum physical profile of 111221; normal color vision required (ch. 10C).
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) paras b(1)-(3) (10C also requires b(5) freedom from vertigo)
- 12K: Under whose auspices is the 12K MOS course conducted?
- The USA Engineer School (DA Pam 611-21 ch. 10C).
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) para b(6)
- 12K: What are examples of additional skill identifiers (ASIs) for 12K?
- P6 – Project Management; Q6 – Protection Cell Operations (DA Pam 611-21 ch. 10C).
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) para c(1)-(2)
- 12K: What does DA Pam 611-21 list as 12K duties at skill level 1?
- Installs steel, plastic, and copper pipes, water closet with tank, urinals, water heaters, shower systems, water systems, waste systems, lavatories, and cross linked polyethylene (PEX) pipes. (ch. 10C)
- DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-12K) para a(1) (MOSC 12K1O)
Keep going: more Engineer decks
- 12BCombat Engineer418 cards
- 12NHorizontal Construction Engineer337 cards
- 12WCarpentry and Masonry Specialist243 cards
- 12RInterior Electrician165 cards
- 12YGeospatial Engineer129 cards
- 12HConstruction Engineering Supervisor114 cards
Not your job? Use the MOS deck finder or see every MOS deck by career field.