US Army Flashcards

Home › MOS decks › 92W

Supply and Services · MOS 92W

Drill 92W: Water Treatment Specialist flashcards

This page puts every 92W card in one place: 168 questions and answers for the Water Treatment Specialist job, spread across 4 decks.

Open 92W in the appJump to the cards

How to drill 92W

  1. Supply cards cover classes of supply, forms and systems. Write the list from memory before each round, then check it.
  2. Pick one deck below and cover the answers with your hand or a sheet of paper.
  3. When a deck feels easy, open 92W in the app and choose Practice test. It asks multiple-choice questions built from these same cards.

With 168 cards, try about 7 short rounds of 25 cards instead of one long session. One or two rounds a day keeps it fresh.

92W decks on this page

92W – Deep Dive 3: Duties, Water Standards, Organizations and Planning

Source: DA Pam 611-21 ch. 10C (Oct 2026 copy; 10-92W marked effective 202510); ATP 4-44/MCRP 3-40D.14 Water Support Operations (16 Sep 2025, incl. C1 8 Jul 2026). Supplementary study aid – verify against current editions on armypubs.army.mil.

92W: Besides water treatment, what inspection duty does DA Pam 611-21 give the 92W?
Inspecting facilities and food suppliers for disease-causing agents, germs and environmental hazards.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wa
92W: What laundry role does a 92W have in Field Hospitals?
They serve as laundry equipment operators, overseeing the sanitary operation of laundry facilities.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wa
92W: What does a 92W10 do when water quality indicators drift off standard?
Reports the deviations to supervisors. The 92W10 also keeps records of test results and equipment maintenance.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wa(1)
92W: Besides purifying water, what does a 92W20 do with test results?
Analyzes water samples, interprets the results and adjusts the treatment process. The 92W20 also manages stock levels of chemicals and supplies.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wa(2)
92W: What water reconnaissance duty does a 92W30 have?
Directs water reconnaissance, identifying and developing new water sources.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wa(3)
92W: At what echelon does a 92W30 manage water supply operations, and what CBRN duty do they have?
Battalion/brigade level. They employ CBRN detection and purification techniques to keep water sources free of CBRN contamination.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wa(3)
92W: For which echelons does a 92W40 direct water reconnaissance and water point development?
Division, corps and echelons above corps. The 92W40 also develops area water supply and treatment plans and advises commanders on water supply.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wa(4)
92W: What staff duties does a 92W40 perform?
Staff and advisory duties related to water and laundry operations.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wa(4)
92W: What are the minimum OPAT scores for 92W?
Standing Long Jump 140 cm, Seated Power Throw 400 cm, Strength Deadlift 140 lbs and Interval Aerobic Run 40 shuttles (Significant, Gray).
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wb(4)(b)
92W: Besides the Quartermaster School course, how else can someone qualify as a 92W?
By meeting the ACASP criteria in AR 601-210. Waivers go to the Quartermaster Commandant's Enlisted Proponent Office.
DA Pam 611-21 ch. 10C (Oct 2026 copy), para 10-92Wb(5)
92W: Is water treatment a field service or a supply function in the Army?
Water treatment is a field service. Purification, quality surveillance, storage and distribution of potable and non-potable water are supply functions. (In the Marine Corps they are general engineering.)
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-2
92W: How is raw water classed as fresh, brackish or salt?
By total dissolved solids (TDS): fresh is under 1,500 mg/L, brackish is 1,500–30,000 mg/L, and salt is 35,000 mg/L or more.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-4
92W: What is the difference between potable and palatable water?
Potable water is treated, disinfected and judged safe to drink by preventive medicine, even if it tastes bad. Palatable water is pleasant to drink but not necessarily safe.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-5
92W: Name the activities that require potable water.
Drinking, ice for food preservation and cooling, dining facility operation, medical treatment, personal hygiene, and testing and flushing potable water hoses and pipelines.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-5
92W: If non-potable water must be used, which kind is preferred?
Water with the lowest TDS available. Brackish and salt water are minimally acceptable and can cause significant corrosion in construction or engineering use. Preventive medicine approves the use.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-6
92W: How must potable and non-potable water containers be labeled?
"Potable Water Only" (cleaned and sanitized, per AR 700-136) and "Non-Potable Water – Do Not Drink."
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 1-7 and 1-8
92W: Can a container that once held POL or herbicides be cleaned for potable water?
No. There is no sanitary procedure to remove such contaminants completely, so never use it for potable water.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-8
92W: Is potable water still potable if stored in a non-potable container?
No. It may only be used for non-potable purposes.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-8
92W: What form records an inspection of a potable water container?
DA Form 5457 (Potable Water Container Inspection), or the DOEHRS Water Container Inspection Survey, used by preventive medicine personnel.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-7
92W: What is the difference between short-term and long-term potability standards?
Short-term covers under 30 consecutive days and ensures no dangerous pathogens such as E. coli. Long-term covers over 30 days, is stricter and is based on EPA drinking water regulations.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 1-10 and 1-11
92W: What standard governs commercial bottled water bought by the military?
MIL-STD-3006C, which incorporates FDA regulations 21 CFR 129 and 21 CFR 165.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-12
92W: What does an expeditionary water packaging system need in order to bottle water?
A potable water source: it must be connected to a water treatment system or receive bulk water deliveries. Contractors under USAMC normally run these systems.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-15
92W: What is hypo-chlorination?
Using a hypo-chlorinator to feed calcium or sodium hypochlorite to keep a disinfectant residual in stored water.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-16
92W: Where is water first stored at the water treatment area?
In 3,000-gallon collapsible fabric tanks.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-17
92W: What is the HIPPO?
The load handling system compatible water tank rack, a hard-shell tank organic to the water platoon's storage section, which truck companies use to move and distribute water.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-22
92W: Which form captures water issue history, and why does it matter?
DD Form 1715 (Daily Water Issue Log). Accurate history lets planners and water treatment specialists forecast future demand.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-23
92W: What tools do sustainment planners use for water consumption estimates?
The Operational Logistics (OPLOG) Planner and the Water Planning Guide; the guide is on the Quartermaster School Petroleum and Water Department website.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 1-31
92W: Who is the DOD executive agent for land-based water resources?
The Secretary of the Army (DODD 4705.01E), so the Army is the lead service for water management in a joint operations area.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-3
92W: What is the JWRMAG, and who designates its chair?
The joint strategic organization for resolving water issues; the Secretary of the Army designates the chair, and each DOD component has a representative.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-4
92W: What does the Theater Petroleum Center do for bulk potable water?
Helps combatant commands, theater Armies, corps and TSCs develop bulk water policies and plans, gives bulk potable water planning support at TSC level or above, and helps work out transportation needs.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-28
92W: What does the quartermaster (POL and water) group do for water?
Provides planning, liaison and supervision of theater water supply and distribution, and centrally manages bulk water by receiving, consolidating and tracking water accountability reports. It is normally assigned to the TSC or an ESC.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-29
92W: Who builds and maintains petroleum and water facilities for the quartermaster (POL and water) group?
Engineers; the group depends on external engineer support for construction, rehabilitation and maintenance of those facilities.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-31
92W: Do maneuver brigades have organic water treatment systems?
No. They depend on a water purification company or composite supply company attached or OPCON to a CSSB. The BSB has no organic water production or storage section.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 2-36 and 2-46
92W: What bulk water carriers can CSSB truck companies haul?
5,000-gallon semi-trailer mounted fabric tanks (SMFTs) on M872 trailers, and the 2,000-gallon HIPPO by LHS or PLS.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-37
92W: How much can one water support company platoon produce per day?
Up to 150,000 gallons from a fresh source or 100,000 gallons from a brackish or contaminated source.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-39
92W: What are a water support company's overall capabilities?
Three platoons that produce 300,000–450,000 gallons a day, store 120,000 gallons and distribute 20,000 gallons per platoon in one turn.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-39
92W: What does a TWDS detachment provide?
Up to 10 miles of hoseline (to the corps rear) to move large volumes of water from a water treatment area to a storage or distribution point.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-40
92W: Which components hold most water support companies?
The Army National Guard and Army Reserve.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-40
92W: How much water can a composite supply company purify, store and issue?
120,000 gallons of potable water. Its water production section has four 1,500-GPH TWPS (30,000 gal per TWPS from fresh water, 24,000 from brackish).
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 2-42 and 2-44
92W: How much can a CSC water storage section store?
80,000 gallons in its two WSDSs, plus up to 60,000 gallons in HIPPOs when they aren't being used for distribution.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-44
92W: How many people can a CSC shower and laundry section support?
5,000 personnel per week, using two laundry advanced systems and two twelve-head shower trailers; it also provides CBRN decontamination.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-44
92W: Does the BSB distribution company's water section treat water?
No. The water section in its fuel and water platoon stores and distributes water but relies on the CSC for treatment.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-53
92W: What water equipment is organic to a forward support company?
The M149 400-gallon water trailer ("water buffalo") and the 800-gallon unit water pod system ("Camel II").
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 2-57
92W: Where should water production be placed relative to end users?
As close as possible, to cut transportation and distribution needs. If that isn't possible, consider storing large quantities centrally and forward.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-19
92W: What is QLET, compared with OPLOG Planner?
A lighter, quicker version of OPLOG Planner that gives logistics estimates (weight, short tons, gallons, pallets, platforms) for chosen standard requirements codes; less detailed.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-113
92W: Why might local laws require approval before setting up a tactical water production site?
Some states and nations treat water treatment as an industrial process producing industrial waste. Local laws may also require a dig permit for wells or site work.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-120
92W: Why do water treatment production rates drop in extreme cold?
Water is more viscous and moves slower through pumps, and disinfection chemicals need more time, so flow must be slowed. Drain all components when not in use to prevent freezing.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-122
92W: Down to what temperature can current water systems operate?
-25°F and above, while arctic winter extremes run -65 to -50°F.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-129
92W: Why should cool water be provided in tropical and arid areas?
To encourage personnel to drink large quantities and prevent heat injuries.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 3-124 and 3-125
92W: In arid regions, what water assumption should planners make, and what may water units have to do early?
Assume no host-nation water. Water units may deploy early to reconnoiter raw water sources, bore new wells and set up central water points, ideally near the shore or offshore.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 3-126 and 3-127
92W: What are the dominant water sources in arctic regions, and what is needed to reach them?
Unfrozen water beneath frozen rivers and lakes, or wells. Engineer support or a power auger is needed to drill through ice and frozen ground; bring extra hoses and pumps.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-130
92W: What is the difference between universal and sustaining unit-level water requirements?
Universal covers drinking, personal hygiene and individual meal preparation, the minimum for every unit. Sustaining adds functional needs such as hygiene, field feeding, medical, mortuary affairs, CBRN, engineer and maintenance.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 3-132 and 3-133
92W: In what units are water planning factors expressed?
Gallons of water per person per day.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-131
92W: Who makes up the ideal water reconnaissance team?
A water treatment specialist, preventive medicine, engineer and CBRN personnel.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-141
92W: Which units should be located near a water supply point for mutual support?
Laundry, bath and personnel decontamination units. Field rations and water points should also be collocated to enhance resupply.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-142
92W: What makes a water source satisfactory?
Enough quantity for the supported force, quality that can be purified to military standards, and sustainability over the long term.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-143
92W: What four raw water characteristics does a 92W analyze during water reconnaissance?
Turbidity, TDS, pH and temperature.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-144
92W: What does the M272 Chemical Agents Water Testing Kit detect?
Hazardous levels of lewisite, nerve, cyanide and mustard agents, using visual color-comparison tests.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-144
92W: What does the M329 Joint Chemical, Biological, Radiological Agent Water Monitor do?
Detects and presumptively identifies biological agents (two per handheld assay) and detects and quantifies gross alpha and beta radiological contamination in water.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-144
92W: Why shouldn't water reconnaissance rely only on military maps?
They may be incomplete or outdated for water sources; frequently updated satellite imagery is better, and air reconnaissance should precede ground reconnaissance when possible.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-145
92W: What is the best way to get accurate information for selecting a water site?
Ground reconnaissance; water treatment specialists do the on-site water quantity and quality analysis.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-146
92W: What form records a proposed water site during the site survey?
DD Form 1712 (Water Reconnaissance Report). Section 1 covers source quality and quantity; section 2 covers site conditions such as security and drainage, plus a scaled site sketch.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 3-147 to 3-150
92W: Where should coastal water treatment systems be located?
On sheltered bays, harbors, lagoons or inlets rather than open coastlines, to avoid surf turbulence and storm surge.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-151
92W: How long is the average interval between high tides?
About 12 hours 25 minutes, so two highs and two lows occur every 24 hours 50 minutes (a lunar day).
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-152
92W: How can you tell the height of high tide at a potential coastal water site?
Look for the distinct line of debris left on shore by the high tide, and observe the site at both high and low tide.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-153
92W: If preventive medicine isn't present at a water reconnaissance, what does the 92W do?
Collects raw water samples and submits them to supporting preventive medicine personnel after the reconnaissance.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-155
92W: What engineer form accompanies the DD Form 1712?
DD Form 3015 (Engineer Reconnaissance Report), recording work description, work hours, equipment and materials needed.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 3-157

92W – Deep Dive 4: Water Quality, Safety, Equipment and Treatment

Source: ATP 4-44/MCRP 3-40D.14 Water Support Operations (16 Sep 2025, incl. C1 8 Jul 2026). Supplementary study aid – verify against current editions on armypubs.army.mil.

92W: Who acts as the primary distribution and materiel manager in a BSB distribution company's water section?
The senior water treatment NCO, because the water section is very small.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 4-119
92W: What can a BSB distribution company water section run and hold?
One water point and 20,000 gallons of water; it can move all 10 of its organic HIPPO tank racks with its own transportation.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 4-120
92W: Is potable water usually returned (retrograded) once delivered?
No. It is consumed quickly, so it is more efficient to delay or cancel a delivery than to return water.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 4-22
92W: Is chlorinated water wastewater when it is disposed of, and what rules apply?
Yes. Wastewater disposal falls under EPA, local or host-nation rules and usually needs a permit; supply units carry it out.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 4-24 and 5-34
92W: What is the joint fuel and water board?
A recurring meeting, led or joined by the TSC, that synchronizes liquid logistics across the services, identifies critical shortfalls and sets support priorities.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 4-48
92W: Who decides whether water of low physical quality may be used?
The appropriate command level, based on medical recommendations.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-1
92W: What are the principal physical characteristics of water?
Color, odor, taste, turbidity and temperature.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-3
92W: Why was the turbidity standard established?
To make disinfection more efficient by reducing the particles microorganisms attach to.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-3
92W: What is the optimal drinking water temperature for hydration and palatability?
60°F (16°C). Colder water also slows disinfection and reduces reverse osmosis capacity.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-3
92W: Are there set standards or tests for odor and taste?
No. The treatment process removes tastes and odors that make water unpalatable.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-3
92W: At what concentration does chloride start to cause laxative effects?
Above 600 mg/L. Its poor taste also leads people to drink less and become dehydrated.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-6
92W: How does high TDS degrade performance?
Through dehydration, either because people reject the water or from chemically induced diarrhea; the risk rises with TDS level.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-7
92W: What toxic agent can form when water containing hydrogen cyanide is chlorinated?
Cyanogen chloride.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-9
92W: What is the main contributor to water hardness, and how is hardness expressed?
Magnesium (with calcium); hardness is expressed as equivalent calcium carbonate.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 5-11 and 5-13
92W: How is lindane, a pesticide, likely to get into a well?
By being spilled around the well during mixing, or from repeated applications in the surrounding area; it also enters water from aerial spraying and runoff.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-10
92W: Who measures radioactivity in bulk water supplies?
Water treatment specialists and preventive medicine personnel.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-18
92W: Who tests bottled or packaged water lots on receipt at a storage facility or issue point?
Veterinary personnel. Preventive medicine tests packaged water, major storage sites and host-nation water.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-19
92W: What standards should host-nation water comply with?
STANAG 2136, STANAG 2629 or other applicable multinational agreements.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-19
92W: Can water be potable without disinfection?
No. No other treatment process reliably removes all disease-producing organisms, so water must be disinfected to be potable.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-24
92W: What affects how well chlorine disinfects water?
The form of chlorine, pH and contact time; the type, density and chlorine resistance of organisms; other chlorine-demanding substances; mixing; and adding enough chlorine to leave a residual.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-25
92W: Who may authorize reduced or higher chlorine residuals, and why?
The command surgeon: reduced levels to conserve low chlorine supplies, or higher residuals and longer contact times where chlorine-resistant organisms like Entamoeba histolytica and Giardia lamblia are widespread.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-26
92W: Why isn't a lack of symptoms after drinking untreated water proof it is safe?
Waterborne diseases have an incubation period, generally 1–3 days. Healthy locals prove nothing either, since they may have immunity.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras 5-27 and 5-28
92W: How is CBRN-contaminated raw water made safe?
Feed-water filters and RO elements remove most agents, but product water must also pass through a CBRN filter to reach safe levels.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-29
92W: List the general safety precautions for operating a water treatment system.
Ground the system (and any separate generator), block trailer wheels, keep fire extinguishers and a fire point, lock support legs down, wear hearing protection, post NO SMOKING signs, and keep chemicals out of sunlight with aprons, gloves and goggles.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-31
92W: What are the three categories of water treatment wastewater?
Brine wastewater, filter backwash wastewater and membrane cleaning wastewater.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para 5-34
92W: How close to the raw water source must the LWP be, and what area does it need?
No more than 50 feet from the source, on a 75 x 75-foot area.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-3
92W: How much does the LWP produce from salt water, and what technology does it use?
75 GPH from salt water (125 GPH fresh), using ultrafiltration and reverse osmosis.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-3
92W: How many people does the LWP take to unload, set up and operate?
Four to six to unload, two to set up, and at least two to operate.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-3
92W: What extra items does the LWP need in freezing temperatures?
A cold weather kit, plus an additional 3-kW generator and a tent. It is designed for -25°F to 120°F.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-3
92W: What tanks and generator come with the LWP?
One 1,000-gallon product tank, one 1,000-gallon settling tank and a 3-kW tactical quiet generator.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-4
92W: How far from the source and on how much area is the TWPS set up?
No more than 330 feet from the raw water source, on a 75 x 100-foot area.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-7
92W: What does the TWPS produce from salt water, and what technology does it use?
1,200 GPH from salt water (1,500 GPH fresh), using microfiltration and reverse osmosis.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-7
92W: What is the maximum source water temperature for the TWPS, and how many people run it?
Source water can't be over 100°F. Three people set it up and at least three operate it.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-7
92W: What tanks and generator come with the TWPS?
Two 3,000-gallon product tanks (9,000 more with the extended distribution kit), a 1,000-gallon microfiltration feed tank, a 1,500-gallon cleaning waste tank and a 60-kW tactical quiet generator.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-8
92W: Which Army water purifier has the highest production, and how is it mounted?
The 3,000-GPH ROWPU, housed in an 8 x 8 x 20-foot ISO container on an M871 30-foot trailer.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-10
92W: What are the ROWPU's salt water output, source distance and footprint?
2,000 GPH from salt water (3,000 fresh); no more than 200 feet from the source; a 35 x 70-foot area.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-11
92W: What filtration does the ROWPU use before reverse osmosis, and what is its operating range?
Media filtration. It operates from -25°F to 110°F and needs a winterization kit below 32°F.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-11
92W: How many product tanks does the ROWPU have?
Three 3,000-gallon product tanks.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-12
92W: What is the Marine Corps PWPS's output, and can it treat CBRN-contaminated water?
At least 18 GPH from seawater or 22 GPH from fresh water, meeting short-term (<30 days) standards. It cannot treat CBRN-contaminated water.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-20
92W: What are the two sizes of potable WSDS, and what tanks do they use?
The 40,000-gallon WSDS (three 20,000-gallon tanks, one a spare) and the 800,000-gallon WSDS (sixteen 50,000-gallon tanks).
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras A-23 and A-24
92W: What are the four basic components of a WSDS?
Tanks, pumps, a hypochlorinator and distribution equipment.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-24
92W: What makes up the FAWPSS?
Four 500-gallon fabric drums (two connected at a time), a 150-GPM pump unit, hoses and four dispensing nozzles. Three drums fit on a PLS flat rack.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-29
92W: What is on a HIPPO, and down to what temperature does it keep water from freezing?
A 2,000-gallon tank rack with pump, filling station, 70-foot hose reel and bulk hoses. It prevents freezing down to 25°F; at 32°F and below, operators apply the freeze prevention steps.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-30
92W: What must commanders do when arctic temperatures will drop below -25°F?
Conduct risk assessments and add measures such as heating blankets and tents to offset equipment limits.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-31
92W: Who owns the 5,000-gallon SMFTs?
They are kept in Army prepositioned stocks, not organic to any quartermaster or transportation unit, and must be requisitioned for truck companies to haul on M872 trailers.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-33
92W: What is the Camel II's freeze protection range, and how does it dispense water?
Its integrated freeze protection works from 25°F to 130°F. It has single-point dispensing for cold weather and six filling positions for canteens and 5-gallon cans.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-34
92W: What is the NSN for the five-gallon water can?
7240-00-089-3827 (replacement lid 7240-00-089-7312).
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-38
92W: What throughput can the early entry fluid distribution system move?
650,000 gallons of raw non-potable water per 20-hour day through a trace up to 50 miles long.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para A-39
92W: How many days of treatment chemicals does a 92W normally deploy with?
At least 30 days, based on 20 hours of operation per day, adjusted by mission analysis.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-4
92W: What is the most accurate way to estimate chemical resupply for a water treatment system?
Analyzing historical chemical consumption; the equipment TM and the Water Planning Guide can also be used.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-5
92W: What are the parts of a typical water site?
A raw water source, water intake point, treatment area, storage area and issue point.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-7
92W: How do you convert gallons of water to pounds, and vertical feet of water to psi?
Pounds = gallons × 8.34; psi = vertical feet of water × 0.43 (and feet = psi × 2.3).
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), table B-2 (para B-8)
92W: How many gallons are in a cubic foot of water, and what does a cubic foot weigh?
About 7.5 gallons, weighing 62.4 pounds.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), table B-2 (para B-8)
92W: How level must the ground be for collapsible water storage bags?
Less than a 3-degree slope in 100 yards, and clear terrain.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-11
92W: How should a water point along a road be laid out so it doesn't block traffic?
With a turnout: a widened section of the main road or a new one-way road past the water point.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-13
92W: Where should the suction hose intake screen sit in the water?
At least 8 inches below the water level and 8 inches above the bottom, with an intake screen used however clear the water looks.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-17
92W: Why must the raw water intake hose be airtight?
The pump must create a partial vacuum in the suction line; suction lift also decreases at higher altitudes.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-18
92W: What do you do when a stream won't cover the intake screen with at least 4 inches of water?
Dig a pit (lined with gravel in clay or silt bottoms) or use a bucket shield. A dam can also raise the water level in small streams.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras B-21 and B-22
92W: What is the chief advantage of a float intake?
The screen is easy to adjust vertically, which helps in large streams with uneven quality or where water near the banks is shallow.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-23
92W: What advantages does groundwater have over surface water?
It is more abundant, often cleaner, needs less treatment, is easier to protect and seal from contamination, and isn't affected by short-term drought.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-26
92W: What is the difference between a spring and a seep?
A spring emerges at the surface with a distinct current; a seep has no distinct current.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-27
92W: Name the five types of wells by construction method.
Dug, bored (augers), driven (drive point), jetted (high-velocity water jet, or steam in some arctic areas) and drilled (percussion or rotary).
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-31
92W: What are a well's static level, pumping level and drawdown?
Static level is the depth to water before pumping. Pumping (dynamic) level is where it stabilizes during steady pumping. Drawdown is the difference between them.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), paras B-32 to B-34
92W: What is a well's specific capacity?
Its yield per foot of drawdown, usually in GPM per foot.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-38
92W: Why are saltwater beach wells preferred to offshore intakes, and what is their drawback?
They avoid tide, surf and shallow-water problems and can be concealed behind the shoreline. They may bring hydrogen sulfide (rotten-egg odor) from sulfur-reducing bacteria.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-40
92W: What is the OISS, and is it part of the ROWPU?
The offshore intake system that jets wellheads or creates offshore intakes to feed seawater to a TWPS or ROWPU. It is a TWPS component; for the ROWPU it must be bought separately.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-42
92W: When should OISS wellpoints be installed on a coast?
At maximum (extreme) low tide, so they don't need to be moved as tides change.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-44
92W: How can a 92W reduce hydrogen sulfide in raw water?
Aerate it by spraying it into a 3,000-gallon raw water tank (turning the gas into free sulfur that filters remove) and add citric acid to bring pH to 4–5.
ATP 4-44 (16 Sep 2025, incl. C1 8 Jul 2026), para B-45

92W – Water Treatment Specialist

Source: DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W); DA Pam 611-21 table 10-1 (92W 3-7); ATP 4-44 (Sep 2025, incl. C1 8 Jul 2026) (Water Support Operations); TB MED 577 (1 May 2010).

92W: What is the primary role of the Water Treatment Specialist?
Status: current MOS (DA Pam 611-21 ch. 10C). To purify, store, distribute, and test water for drinking and other uses in the field.
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para a)
92W: What doctrine covers water support operations?
ATP 4-44/MCRP 3-40D.14, Water Support Operations (September 2025, incorporating Change 1 of 8 July 2026).
ATP 4-44 (Sep 2025, incl. C1 8 Jul 2026) (supersedes ATP 4-44/MCRP 3-40D.14, 16 Dec 2022)
92W: What system purifies water in the field?
Reverse-osmosis systems: the 1,500-GPH Tactical Water Purification System (TWPS) and the 125-GPH Lightweight Water Purifier (LWP). Both can purify fresh, brackish, salt, and CBRN-contaminated water.
ATP 4-44 (Sep 2025, incl. C1 8 Jul 2026), paras 2-9, 2-44, A-2, A-6
92W: What is reverse osmosis?
Forcing water through a semi-permeable membrane to remove contaminants.
ATP 4-44 (Sep 2025, incl. C1 8 Jul 2026), para E-10 (filtered water pumped at high pressure against a semipermeable membrane that passes product water and rejects suspended and dissolved impurities)
92W: Why is chlorine residual tested?
To make sure enough disinfectant stays in the water to protect storage and distribution systems from recontamination. Reverse-osmosis-treated water is chlorinated at the production site to 2.0 mg/L free available chlorine (FAC) after a 30-minute contact time; 92Ws keep FAC at 1.0 mg/L at potable water issue points, and at least 0.2 mg/L must remain in unit-level containers.
ATP 4-44 (Sep 2025, incl. C1 8 Jul 2026), paras 1-18 to 1-19, 5-24, E-3; TB MED 577/NAVMED P-5010-10/AFMAN 48-138_IP (1 May 2010), para 2-5b(2)(a)(i), (b), (c) and table 2-6 (2 mg/L FAC after 30-min contact at production; at or above 1.0 mg/L at bulk issue points; at least 0.2 mg/L in unit-level containers)
92W: How does DA Pam 611-21 summarize the 92W major duties?
The Water Treatment Specialist is primarily responsible for supervising and installing water purification equipment, ensuring clean water storage and availability, and performing water quality tests to detect potential contaminants. (ch. 10C)
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para a)
92W: What minimum ASVAB line score does DA Pam 611-21 list for 92W?
88 in GM (General Maintenance) (ch. 10C; verify current standards).
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para b(4)(a))
92W: What physical demands rating applies to 92W?
Significant (Gray), with a minimum physical profile of 211221; normal color vision required (ch. 10C).
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para b(1)-(3))
92W: Under whose auspices is the 92W MOS course conducted?
The U.S. Army Quartermaster School (DA Pam 611-21 ch. 10C).
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para b(5))
92W: What are examples of additional skill identifiers (ASIs) for 92W?
D6 – Operational Data Analyst (DA Pam 611-21 ch. 10C).
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para c)
92W: What does DA Pam 611-21 list as 92W duties at skill level 1?
Collect and test water samples, following established procedures. (ch. 10C)
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para a(1))
92W: What does DA Pam 611-21 list as 92W duties at skill level 2?
Purify water using various treatment methods, ensuring potable water standards. (ch. 10C)
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para a(2))
92W: What does DA Pam 611-21 list as 92W duties at skill level 3?
Supervise water purification operations, ensuring quality control and compliance with regulations. (ch. 10C)
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para a(3))
92W: What does DA Pam 611-21 list as 92W duties at skill level 4?
Manage all aspects of water treatment facilities, including personnel, equipment, and resources. (ch. 10C)
DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92W, eff 202510, para a(4)); DA Pam 611-21 table 10-1 (92W graded E-3 to E-7)
92W: What is the LWP?
The 125-GPH Lightweight Water Purifier, a reverse-osmosis system that gives sustainment units potable water for small units and detachments where bulk water distribution is not feasible. It can purify all water classifications, including CBRN-contaminated water.
ATP 4-44 (Sep 2025, incl. C1 8 Jul 2026), para A-2

CMF 92 – Supply and Services Common Knowledge

Source: ADP 4-0 (23 Mar 2026, incl. C1 Aug 2026); FM 4-0 (20 Mar 2026) (app. A Quartermaster operations; app. E LOGSTAT); AR 710-4 (15 Apr 2026); AR 710-2 (1 Jul 2024); AR 735-5 (30 Apr 2026); DA Pam 710-2-2 (1 Jul 2024); ATP 4-42 (2 Nov 2020); ATP 4-42.2 (18 Sep 2024); DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92Z eff 202610); AUSA (1 Oct 2026).

CMF 92: Where is the Quartermaster School?
Fort Lee, VA (renamed from Fort Gregg-Adams in 2025).
DA Pam 611-21 ch. 10C (Oct 2026 copy) (e.g., 10-92G para b(7), 10-92W para b(5): waivers to the Quartermaster Commandant, Ft Lee, VA 23801); HQDA GO 2025-16 (Fort Gregg-Adams redesignated Fort Lee, 11 Jun 2025)
CMF 92: What is the Quartermaster Corps motto?
"Supporting Victory."
FM 4-0 (20 Mar 2026), app. A introduction ("The Quartermaster regimental motto is 'Supporting Victory.'")
CMF 92: What is the sustainment capstone doctrine?
ADP 4-0, Sustainment.
ADP 4-0 (23 Mar 2026, incl. C1 Aug 2026) (title: Sustainment; supersedes ADP 4-0, 31 Jul 2019)
CMF 92: What are the principles of sustainment?
Integration, synchronization, anticipation, responsiveness, simplicity, economy, survivability, continuity, and improvisation (nine principles; ADP 4-0 says the principles of sustainment and of logistics are the same).
ADP 4-0 (23 Mar 2026, incl. C1 Aug 2026), paras 1-23 to 1-32, fig. 1-1
CMF 92: What is 92Z?
Senior Noncommissioned Logistician – since 1 October 2026, the consolidated MSG/SGM MOS for master sergeants from 92A, 92F, and 92Y (HRC via AUSA). The Oct 2026 10C entry says a 92Z must be qualified at SFC in one of seven MOSs: 92A, 92Y, 92F, 92G, 92M, 92R, or 92S.
AUSA "Army Adds 4 New MOSs" (1 Oct 2026); DA Pam 611-21 ch. 10C (10-92Z, effective 202610)
CMF 92: What is a LOGSTAT?
A logistics status report showing on-hand quantities and requirements for key supply classes.
FM 4-0 (20 Mar 2026), paras E-1 to E-3 (LOGSTAT: on-hand stockage and 24/48/72-hour projections; identifies requirements and critical shortages)
CMF 92: What is the difference between expendable, durable, and nonexpendable property?
Expendable is consumed in use; durable is not consumed but doesn't require property book accountability (e.g., hand tools); nonexpendable requires property book accountability.
AR 710-4 (15 Apr 2026), para 4-5d (all Army property is classified expendable, durable, or nonexpendable; ARC criteria in app. C); glossary (durable item; expendable items; nonexpendable items); paras 4-1, 5-3 (durable hand tools)
CMF 92: What is GCSS-Army?
The Army's enterprise logistics system for supply, maintenance, and property management.
FM 4-0 (20 Mar 2026), para D-2; ATP 4-42 (2 Nov 2020), paras 2-16 to 2-17
CMF 92: What are the ten classes of supply, by number and general meaning?
I subsistence (rations, bottled/packaged water); II clothing, individual equipment, tentage, tool sets and kits, maps, administrative and housekeeping supplies, and small batteries for handheld devices; III petroleum, oils, and lubricants (bulk and packaged); IV fortification, barrier, and construction materials; V ammunition of all types; VI personal-demand items; VII major end items; VIII medical materiel (including medical device repair parts, blood, and blood products); IX repair parts (including large vehicle batteries); X items that support nonmilitary programs such as agricultural and economic development.
FM 4-0 (20 Mar 2026), para A-8 (classes of supply)
CMF 92: What is an SSA?
A Supply Support Activity — the supply activity that supports units with requested supplies, usually at brigade or higher, often with an authorized stockage list. 92A Soldiers commonly work in or with an SSA; 92Y Soldiers request support from it.
ATP 4-42 (2 Nov 2020), para 1-7 (SSA: an activity assigned a DOD activity address code with a supply support mission, JP 4-09) and para 3-169 (BSB company executes SSA operations); ATP 4-42.2 (18 Sep 2024), para 1-5 (authorized stockage list)
CMF 92: What is a hand receipt in CMF 92 practice?
A document (commonly DA Form 2062 or the current GCSS-Army equivalent) that records who is responsible for property. Sub-hand receipts push responsibility to a user or section; they do not relieve the primary hand receipt holder of all duties.
AR 710-4 (15 Apr 2026), glossary (hand receipt; sub-hand receipt: does not transfer direct responsibility, but does transfer personal responsibility), app. E table E-18 (DA Form 2062 as a hand receipt)
CMF 92: What is the difference between a property book and a hand receipt?
The property book is the formal accountable record for nonexpendable (and designated) property, kept by the property book officer (PBO), normally at battalion or brigade level, in GCSS-Army. Hand receipts issue that property to commanders, supervisors, and users. Losses are investigated under AR 735-5.
AR 710-4 (15 Apr 2026), paras 4-5d–e (nonexpendable property requires formal property book accounting), 4-9c (PBO accountable for property in use at organizational level, hand receipted to PHRHs); AR 735-5 (30 Apr 2026)
CMF 92: What is a cyclic inventory?
An inventory of a portion of the stock or property on a scheduled cycle so the entire account is counted over time, rather than only at one annual event. Frequency follows regulation and the commander's or PBO's plan.
AR 710-4 (15 Apr 2026), para 16-2a (written inventory plans approved by the APO; wall-to-wall, cyclic, sampling, "by exception"), para 1-21 (annual/cyclic PBO/PHRH inventory); DA Pam 710-2-2 (1 Jul 2024), para 12-3 (SSA cyclic counts: 10 percent monthly over 12 months)
CMF 92: What is a document register, in traditional unit supply terms?
The record of supply requests and related document numbers used to track due-ins, due-outs, and completed actions. In GCSS-Army the same visibility is largely electronic; units may still use local document control procedures.
AR 710-4 (15 Apr 2026), para 1-21 (document register (due-in) accuracy metric) and paras 3-11, 16-27 (nonexpendable document register). DA Pam 710-2-1 is no longer listed on APD.
CMF 92: What is a due-in and a due-out?
A due-in is quantity expected to be received on an open requisition. A due-out is a quantity owed to a supported customer or a shortage against a requirement. 92As manage both in the SSA; 92Ys track open requests at unit level.
DA Pam 710-2-2 (1 Jul 2024), glossary (backorder/due-out; net asset = on hand + due-in − due-out); AR 710-4 (15 Apr 2026), app. E (due-in entries)
CMF 92: Why is "supporting victory" more than a kitchen or warehouse slogan?
Classes I, III, V, VIII, and IX — food, fuel, ammunition, medical, and repair parts — directly determine how long a force can fight. CMF 92 Soldiers generate combat power by making those commodities available, accounted for, and deliverable.
FM 4-0 (20 Mar 2026), app. A introduction (motto "Supporting Victory") and para E-2 (status of ammunition, food, water, and fuel); ADP 4-0 (23 Mar 2026, incl. C1 Aug 2026), para 1-1 (sustainment enables freedom of action, extends operational reach, prolongs endurance)
CMF 92: What should you do if property is missing after an inventory?
Stop, report to the supervisor and PBO or accountable officer, secure the area, and begin the inquiry or investigation process in AR 735-5. Do not quietly "find" a substitute serial number or adjust the count without authority.
AR 735-5 (30 Apr 2026), para 4-1a–b (individuals immediately report LDDT in writing to the supervisor or commander; commanders will not delay reporting pending inquiries)
CMF 92: How does the October 2026 92Z consolidation affect 92A, 92F, and 92Y Soldiers at master sergeant?
Those MOSs consolidate at MSG into 92Z, Senior Noncommissioned Logistician, as announced for 1 October 2026. The 10C entry also describes 92Z qualification from additional feeder MOSs at SFC. Verify current HRC and DA Pam 611-21 text before counseling a Soldier on career maps.
AUSA "Army Adds 4 New MOSs" (1 Oct 2026, citing HRC); DA Pam 611-21 ch. 10C (Oct 2026 copy) (10-92Z, effective 202610, para a); DA Pam 611-21 table 10-1 (92A, 92F, 92Y marked "del 2610")

Keep going: more Supply and Services decks